PARIS, TX ·
OSHA Inspection: TURNER INDUSTRIES GROUP, LLC
Fatality or catastrophe inspection · Safety discipline
At a glance
On , OSHA opened a fatality or catastrophe safety inspection of TURNER INDUSTRIES GROUP, LLC in 1200 19TH ST SW, PARIS, TX 75460 (NAICS 532490). OSHA activity number 348196726.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TURNER INDUSTRIES GROUP, LLC
- Site address
- 1200 19TH ST SW
- City
- PARIS
- State
- TX
- ZIP
- 75460
- Mailing
- 8687 UNITED PLAZA BLVD, BATON ROUGE, LA 70809
What kind of inspection was it?
- Inspection type
- Fatality or catastrophe (M)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 532490
- Employees
- 173
- Ownership type
- Private (A)
Citations
6 citations on file for this inspection.
5(a)(1)
- Issued
- Oct 10, 2025
- Abate by
- Nov 6, 2025
- Penalty
- Initial $16,550 · Current $16,550
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1):The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to caught-in hazards. On or about April 17, 2025 and at times prior thereto employees were exposed to a caught-in hazards when using a large, heavy, motorized door for entry and exit of radiography bay two. The door had open and close operating buttons that would fully cycle the door with only momentary activation of the button(s).
Recent events (2)
- · C (S) $16550
- · Z (S) $16550
1910.36 D01
- Issued
- Oct 10, 2025
- Abate by
- Nov 6, 2025
- Penalty
- Initial $14,188 · Current $14,188
General-duty citation text
29 CFR 1910.36(d)(1):Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge: On or about April 17, 2025 and at times prior thereto employees were exposed to hazards related to egress while working in radiography bay two without access to an exit route door that did require tools or special knowledge of the opening mechanism.
Recent events (2)
- · C (S) $14188
- · Z (S) $14188
1910.36 D02
- Issued
- Oct 10, 2025
- Abate by
- Nov 6, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.36(d)(2): Exit route doors were not free of a device or alarm that could restrict emergency use of the exit route if the device or alarm fails: On or about April 17, 2025 and at times prior thereto employees were exposed to a caught-in hazards when employees needed to use a manual control to open bay door.
Recent events (2)
- · C (S) $0
- · Z (S) $0
1910.36 E01
- Issued
- Oct 10, 2025
- Abate by
- Nov 6, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.36(e)(1): A side-hinged door was not used to connect any room to an exit route: On or about April 17, 2025 and at times prior thereto employees were exposed to caught-in hazard when a hinged door was not available to exit the bay.
Recent events (2)
- · C (S) $0
- · Z (S) $0
1910.37 A03
- Issued
- Oct 10, 2025
- Abate by
- Nov 6, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(a)(3):Exit routes were not free and unobstructed. No materials or equipment may be placed, either permanently or temporarily, within the exit route. The exit access must not go through a room that can be locked, such as a bathroom, to reach an exit or exit discharge, nor may it lead into a dead-end corridor. Stairs or a ramp must be provided where the exit route is not substantially level. On or about April 17, 2025 and at times prior thereto employees were exposed to caught-in hazards when the exit route was not maintained when the side-hinged door was shut to prohibit entry into bay one during active x-ray tasks.
Recent events (2)
- · C (S) $0
- · Z (S) $0
1910.145 C02 I
- Issued
- Oct 10, 2025
- Abate by
- Nov 6, 2025
- Penalty
- Initial $11,348 · Current $11,348
General-duty citation text
29 CFR 1910.145(c)(2)(i):Caution signs were not used to warn against potential hazards or to caution against unsafe practices. On or about April 17, 2025 and times prior employees were exposed to caught in hazards while ingress/egressing through the bay doors of the radiography building without caution signs posted to warn employees of the crushing hazards from the door closure mechanism.
Recent events (2)
- · C (S) $11348
- · Z (S) $11348
More inspections at Turner Industries Group, LLC
View Turner Industries Group, LLC's full OSHA safety record →
More inspections in this industry (NAICS 532490)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 348196726.