AURORA, CO —
OSHA Inspection: PIONEER GROUP, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of PIONEER GROUP, INC. in 16920 E QUINCY AVE, AURORA, CO 80015 (NAICS 236220). OSHA activity number 348197138.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PIONEER GROUP, INC.
- Site address
- 16920 E QUINCY AVE
- City
- AURORA
- State
- CO
- ZIP
- 80015
- Mailing
- 925 W. KENYON SUITE # 2, ENGLEWOOD, CO 80110
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 5
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.651 E
- Issued
- Jul 25, 2025
- Abate by
- Jan 15, 2026
- Penalty
- Initial $4,965 · Current $2,483 Reduced
General-duty citation text
29 CFR 1926.651(e): Employees were permitted underneath loads handled by lifting or digging equipment: a) On or before April 18, 2025, and at times prior, as the controlling employer did not ensure that subcontracted employees working in a trench were protected from falling material from a 308 CR Mini Excavator that was being used while an employee was in the trench. This condition exposed employees to crushing hazards.
Recent events (3)
- — F (S) $2483
- — C (S) $4965
- — Z (S) $4965
1926.652 A01
- Issued
- Jul 25, 2025
- Abate by
- Jan 15, 2026
- Penalty
- Initial $4,965 · Current $2,483 Reduced
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section: a) On or before On April 18, 2025, and at times prior, as the controlling employer did not ensure that subcontracted workers were protected from cave-in hazards while working in excavations at the site in excess of six feet deep without an adequate protective system. One employee was observed in the excavation without a protective system exposing them to crush hazards.
Recent events (3)
- — F (S) $2483
- — C (S) $4965
- — Z (S) $4965
1926.701 B
- Issued
- Jul 25, 2025
- Abate by
- Jan 15, 2026
- Penalty
- Initial $2,837 · Current $1,418 Reduced
General-duty citation text
29 CFR 1926.701(b): Protruding reinforcing steel, onto and into which employees could fall was not guarded to eliminate the hazard of impalement: a) On or before April 18, 2025, and at times prior, as the controlling employer, did not ensure that exposed vertical rebar was capped and protected. This condition exposed employees to impalement hazards.
Recent events (3)
- — F (S) $1418
- — C (S) $2837
- — Z (S) $2837
More inspections at Pioneer Group, INC.
View Pioneer Group, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 236220)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348197138.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.