SPRINGFIELD, IL —
OSHA Inspection: GEBHARDT'S ROOFING AND REMODELING, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of GEBHARDT'S ROOFING AND REMODELING, LLC in 1116 N 3RD STREET, SPRINGFIELD, IL 62702 (NAICS 238160). OSHA activity number 348204090.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GEBHARDT'S ROOFING AND REMODELING, LLC
- Site address
- 1116 N 3RD STREET
- City
- SPRINGFIELD
- State
- IL
- ZIP
- 62702
- Mailing
- 3419 DONNA STREET, SPRINGFIELD, IL 62707
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 10
- Ownership type
- A
Citations
10 citations on file for this inspection.
1926.20 B01
- Issued
- Jun 12, 2025
- Abate by
- Jul 15, 2025
- Penalty
- Initial $3,547 · Current $2,483 Reduced
General-duty citation text
29 CFR 1926.20(b)(1): The employer did not initiate and maintain accident prevention programs as necessary to comply with this part: On or about April 23, 2025, employees were exposed to fall hazards and eye injuries and the employer did not establish and maintain a safety program.
Recent events (2)
- — I (S) $2483
- — Z (S) $3547
1926.20 B02
- Issued
- Jun 12, 2025
- Abate by
- Jul 15, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.20(b)(2): The employer did not initiate and maintain a safety program which provides for frequent and regular inspections of jobsites, materials, and equipment to be made by a competent person: On or about April 23, 2025, employees were exposed to fall hazards and eye injuries and the employer did not ensure the worksite was inspected regularly by a competent person.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.102 A01
- Issued
- Jun 12, 2025
- Abate by
- Jul 15, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.102(a)(1): The employer did not ensure employees used eye and face protection equipment when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: On or about April 23, 2025, employees using pneumatic nail guns were exposed to eye injuries from flying debris and the employer did not ensure safety glasses were used.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B01
- Issued
- Jun 12, 2025
- Penalty
- Initial $4,965 · Current $3,476 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface having an unprotected side or edge which was six or more feet (1.8m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest system: On or about April 23, 2025, an employee working from the Equipter drivable debris container was exposed to fall hazards of approximately 8 feet and the employer did not ensure fall protection was used.
Recent events (2)
- — I (S) $3476
- — Z (S) $4965
1926.501 B13
- Issued
- Jun 12, 2025
- Abate by
- Jul 15, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): On or about April 23, 2025, employees performing residential roofing activities were exposed to fall hazards greater than 10 feet and the employer did not ensure fall protection was used.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.503 A01
- Issued
- Jun 12, 2025
- Abate by
- Jul 15, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee who might be exposed to fall hazards: On or about April 23, 2025, employees performing residential roofing activities were exposed to fall hazards greater than 10 feet and the employer did not ensure were trained and able to recognize the hazard, and the fall protection system to be used to eliminate or control the hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.502 D15 I
- Issued
- Jun 12, 2025
- Abate by
- Jul 15, 2025
- Penalty
- Initial $4,965 · Current $3,476 Reduced
General-duty citation text
29 CFR 1926.502(d)(15)(i): The Employer did not maintain a safety factor of at least two as part of a complete fall arrest system: On or about April 23, 2025, an employee performing residential roofing activities was exposed to fall hazards of approximately 9.5 feet and the employer did not ensure only a single personal fall arrest system was attached to the Guardian roof peak anchor.
Recent events (2)
- — I (S) $3476
- — Z (S) $4965
1926.502 D17
- Issued
- Jun 12, 2025
- Abate by
- Jul 15, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(d)(17): The attachment point of the body harness was not located in the center of the wearer's back near shoulder level, or above the wearer's head: On or about April 23, 2025, an employee performing residential roofing activities was exposed to fall hazards and the employer did not ensure the user's fall arrest lanyard was attached at the center of the employee's back.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B01
- Issued
- Jun 12, 2025
- Penalty
- Initial $4,256 · Current $2,978 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: On or about April 23, 2025, employees performing residential roofing activities were exposed to fall hazards of approximately 9.5 feet and the employer did not ensure the multi-position portable ladder side rails extended at least three feet above the roof's eave: a. The ladder on the left side of the rear roof work area did not extend at least three feet above the roof's edge. b. The ladder on the right side of the rear roof work area did not extend at least three feet above the roof's edge.
Recent events (2)
- — I (S) $2978
- — Z (S) $4256
1926.1060 A
- Issued
- Jun 12, 2025
- Abate by
- Jul 15, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would train each employee in the procedures to be followed to minimize hazards related to ladders and stairways: On or about April 23, 2025, employees performing residential roofing activities were exposed to fall hazards of approximately 9.5 feet and the employer did not ensure employees using the ladders were trained.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Gebhardt'S Roofing and Remodeling, LLC
View Gebhardt'S Roofing and Remodeling, LLC's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348204090.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.