Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: REYNALDO GEOVANNY REYES CALERO

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of REYNALDO GEOVANNY REYES CALERO in 3265 MEMORIAL DRIVE, LOTS 601-604 GRAND TERRAZA SUBDIVISION, DECATUR, GA 30032 (NAICS 238130). OSHA activity number 348204645.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Reynaldo Geovanny Reyes Calero — free Get an email when a new federal OSHA severe-injury report for Reynaldo Geovanny Reyes Calero is published. One employer, no account, unsubscribe in one click.
Site address
3265 MEMORIAL DRIVE, LOTS 601-604 GRAND TERRAZA SUBDIVISION
City
DECATUR
State
GA
ZIP
30032
Mailing
5875 HUNT CLUB RUN APT C, NORCROSS, GA 30093
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238130
Employees
11
Ownership type
A

6 citations on file for this inspection.

1926.405 B02

Serious Gravity 5 1 instance 6 exposed
Issued
May 1, 2025
Penalty
Initial $3,783 · Current $3,783
29 CFR 1926.405(b)(2): In energized installations, each outlet box did not have a cover, faceplate, or fixture canopy:  a) On or about April 25, 2025, the employer exposed employees to 120V electrical shock hazards while operating reciprocating and circular saws, impact drills, and battery chargers, in that the outlet box on the power post did not have a cover.
Recent events (1)
  • — Z (S) $3783

1926.1051 A

Serious Gravity 5 1 instance 4 exposed
Issued
May 1, 2025
Penalty
Initial $3,783 · Current $3,783
29 CFR 1926.1051(a): Stairway(s) or ladder(s) were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, or no ramp, runway, sloped embankment, or personnel hoist was provided:  a) Top plate: On or about April 25, 2025, the employer exposed employees to fall hazards of approximately 9-feet to the lower 2nd floor level, in that a ladder or other safe means of access was not provided to access/egress the top plate while engaged in framing activities. Employees were required to climb the framed walls to reach the working level.
Recent events (1)
  • — Z (S) $3783

1926.102 A01

Repeat Gravity 1 1 instance 5 exposed
Issued
May 1, 2025
Penalty
Initial $5,674 · Current $5,674
29 CFR 1926.102(a)(1): Employees were not provided with eye and face protection equipment when machines or operations present potential eye or face injury from physical, chemical, or radiation agents:  a) Ceiling Joists, On or about April 25, 2025, the employer exposed employees to struck-by hazards while operating pneumatic framing nail guns, in that protective eyewear was not provided to employees engaged in framing activities while operating these tools at 150 PSI.  Reynaldo Geovanny Reyes Calero was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.102(a)(1), which was contained in OSHA inspection number 1726955, citation number 1, item number 1, and was affirmed as a final order on  05/14/2024, with respect to a workplace located at 7415 Barclay Court (Lot# 2 Addison Grove Subdivision) Dawsonville, GA 30534.
Recent events (1)
  • — Z (R) $5674

1926.501 B13

Repeat Gravity 5 2 instances 6 exposed
Issued
May 1, 2025
Penalty
Initial $9,458 · Current $9,458
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m)  or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501(b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502:    a) Top plate: On or about April 25, 2025, and at times prior, the employer exposed employees to fall hazards of approximately 30 feet to the lower level, in that a fall protection system was not provided to employees engaged in framing activities.  b) Second level: On or about April 25, 2025, the employer exposed employees to fall hazards of approximately 12 feet to the lower level, in that a fall protection system was not provided to employees engaged in framing while working with an unprotected side or edge.  Reynaldo Geovanny Reyes Calero was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(13), which was contained in OSHA inspection number 1726955, citation number 1, item number 2, and was affirmed as a final order on  05/14/2024, with respect to a workplace located at 7415 Barclay Court (Lot# 2 Addison Grove Subdivision) Dawsonville, GA 30534.
Recent events (1)
  • — Z (R) $9458

1926.403 B01

Repeat 1 instance 6 exposed
Issued
May 1, 2025
Penalty
Initial $378 · Current $378
29 CFR 1926.403(b)(1): Employer did not ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees:   a) On or about April 25, 2025, the employer failed to inspect all electrical extension cords used to provide power to electric tools which employees engaged in framing operations were using, in that the yellow extension cords powering the reciprocating, circular saw, impact drills, and battery chargers, were damaged. An inspection of these cords was not performed prior to the shift as these cords were not repaired or removed from service.  Reynaldo Geovanny Reyes Calero was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.403(b)(1), which was contained in OSHA inspection number 1726955, citation number 2, item number 1, and was affirmed as a final order on  05/14/2024, with respect to a workplace located at 7415 Barclay Court (Lot# 2 Addison Grove Subdivision) Dawsonville, GA 30534.
Recent events (1)
  • — Z (R) $378

1926.404 F06

Other-than-serious 1 instance 6 exposed
Issued
May 1, 2025
Penalty
Initial $0 · Current $0
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous:  a) On or about April 25, 2025, and at times prior, the employer exposed employees to 120V electrical shock hazards while operating reciprocating and circular saws, impact drills, and battery chargers, in that blue and yellow extension cords were missing the grounding pin.
Recent events (1)
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348204645.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.