LOWELL, MA —
OSHA Inspection: JQV CONSTRUCTION CORP.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of JQV CONSTRUCTION CORP. in 198 PLEASANT ST., LOWELL, MA 01850 (NAICS 238160). OSHA activity number 348209305.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- JQV CONSTRUCTION CORP.
- Site address
- 198 PLEASANT ST.
- City
- LOWELL
- State
- MA
- ZIP
- 01850
- Mailing
- 6 EATON STREET APT. 1, BROCKTON, MA 02301
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 13
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.502 D09
- Issued
- Jul 31, 2025
- Penalty
- Initial $5,958 · Current $5,958
General-duty citation text
29 CFR 1926.502(d)(9): Lanyards and/or vertical lifelines did not have a minimum breaking strength of 5,000 pounds (22.2 kN). Location: Roof On or about 4/29/2025, employees were exposed to fall hazards greater than 20 feet to the ground below when using a personal fall arrest system consisting of ropes for vertical lifelines that were damaged, knotted, and/or abraded, reducing their minimum breaking strength to less than 5,000 pounds.
Recent events (1)
- — Z (S) $5958
1926.502 D15
- Issued
- Jul 31, 2025
- Penalty
- Initial $5,958 · Current $5,958
General-duty citation text
29 CFR 1926.502(d)(15): Anchorage points used for attachment of personal fall arrest equipment were not independent of any anchorage point being used to support or suspend platforms and capable of supporting at least 5,000 pounds (22.2 kN) per employee. Location: Roof On or about 4/29/2025, employees were exposed to fall hazards greater than 20 feet to the ground below when using a personal fall arrest system consisting of a Miller RA25-1 reusable roof anchor that was improperly installed, in that, only a total of two 16d duplex nails (two nails per metal flap) were used to secure the ring to the ridge beam. According to the manufacturer, the minimum number of fasteners required to achieve the 5,000 pound anchor strength is a total of twelve (12) new 16d nails OR twelve (12) new #8 2-?" (63.5mm) or longer screws (six on each side) secured into a wood support member through the middle row of holes on the anchor.
Recent events (1)
- — Z (S) $5958
1926.100 A
- Issued
- Jul 31, 2025
- Penalty
- Initial $8,513 · Current $8,513
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets. Location: Roof On or about 4/29/2025, employees were exposed to head injuries while working unprotected on the ground below the roof, where the employer failed to provide them with hardhats, and while other employees were performing roofing activities at a height of an estimated 20 feet above. JQV Construction Corp. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.100(a), which was contained in OSHA inspection number 1760696, citation number 1, item number 1 and was affirmed as a final order on 10/22/2024, with respect to a workplace located at 37 Cardinal Road, Cranston, RI 02921.
Recent events (1)
- — Z (R) $8513
1926.501 B13
- Issued
- Jul 31, 2025
- Penalty
- Initial $11,916 · Current $11,916
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): Location - Roof On or about 4/29/2025, employees were not protected from falling to a lower level while working at heights greater than 6 feet. JQV Construction Corp. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.502(d)(17), which was contained in OSHA inspection number 1760696, citation number 1, item number 2-b and was affirmed as a final order on 10/22/2024, with respect to a workplace located at 37 Cardinal Road Cranston, RI 02921.
Recent events (1)
- — Z (R) $11916
More inspections at JQV Construction Corp.