Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RAUL MORALES CORONA DBA RAUL MORALES CORONA

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of RAUL MORALES CORONA DBA RAUL MORALES CORONA in 6969 FRONTAGE RD., WORDEN, IL 62097 (NAICS 238160). OSHA activity number 348213802.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Raul Morales Corona DBA Raul Morales Corona — free Get an email when a new federal OSHA severe-injury report for Raul Morales Corona DBA Raul Morales Corona is published. One employer, no account, unsubscribe in one click.
Site address
6969 FRONTAGE RD.
City
WORDEN
State
IL
ZIP
62097
Mailing
2748 STATE ST., GRANITE CITY, IL 62040
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238160
Employees
8
Ownership type
A

4 citations on file for this inspection.

1926.416 A01

Serious Gravity 5 1 instance 4 exposed
Issued
Jun 16, 2025
Penalty
Initial $3,547 · Current $3,547
29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means:   a) On or about April 24, 2025, employees were not protected against contact with energized overhead power lines while performing roofing work. The overhead power lines consisted of secondary lines having a voltage rating of 120/240 Volts.   No abatement certification or documentation is required for this item.
Recent events (1)
  • — Z (S) $3547

1926.501 B13

Serious Gravity 10 1 instance 2 exposed
Issued
Jun 16, 2025
Abate by
Jul 14, 2025
Penalty
Initial $4,965 · Current $4,965
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   a) On April 24, 2025, employees engaged in roofing activity were not protected from fall hazards while working at an elevation of approximately 15 feet above the ground.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
  • — Z (S) $4965

1926.503 A01

Serious Gravity 5 1 instance 8 exposed
Issued
Jun 16, 2025
Abate by
Jul 14, 2025
Penalty
Initial $3,547 · Current $3,547
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee who might be exposed to fall hazards:   a) On or about April 24, 2025, employer did not provide training to each employee in order to recognize hazards associated with working at an elevation and to understand procedures to control or minimize those hazards.   In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (S) $3547

1926.1053 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 16, 2025
Abate by
Jul 14, 2025
Penalty
Initial $2,837 · Current $2,837
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:   a) On April 24, 2025, an extension ladder used by employees to access and egress the roof did not have its side rails extended at least 3 feet above the roof eave.   In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (S) $2837