Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: A&S ROOFING SERVICES LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of A&S ROOFING SERVICES LLC in 1774 FLAT SHOALS RD SE LOT108-112, CONYERS, GA 30013 (NAICS 238160). OSHA activity number 348217506.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch A&S Roofing Services LLC — free Get an email when a new federal OSHA severe-injury report for A&S Roofing Services LLC is published. One employer, no account, unsubscribe in one click.
Site address
1774 FLAT SHOALS RD SE LOT108-112
City
CONYERS
State
GA
ZIP
30013
Mailing
1470 BOWMAN RD, LAWRENCEVILLE, GA 30045
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238160
Employees
1
Ownership type
A

2 citations on file for this inspection.

1926.501 B13

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 2, 2025
Abate by
Jun 27, 2025
Penalty
Initial $3,547 · Current $3,547
29 CFR  1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   a) 1774 Flat Shoals Rd SE/ Lot 108-112:  On or about 04/22/2025, the employer exposed employees to fall hazards of 21-feet 2 inches above the lower ground level, in that an adequate fall protection system was not provided to employees while they were installing flashing on a roof with a pitch of 6/12.
Recent events (1)
  • — Z (S) $3547

1926.1053 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 2, 2025
Penalty
Initial $3,547 · Current $3,547
29 CFR  1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder.    a) 1774 Flat Shoals Rd SE/ Lot 108-112: On or about 4/22/2025, the employer exposed employees to fall hazards of than 21-feet 2 inches above the lower level, in that the ladder used to access the roof of the structurer was not extended at least three feet above the upper landing surface.
Recent events (1)
  • — Z (S) $3547

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348217506.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.