Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FRONT-LINE FIRE PROTECTION, LLC

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of FRONT-LINE FIRE PROTECTION, LLC in 376 3RD STREET, EVERETT, MA 02149 (NAICS 238220). OSHA activity number 348220385.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Front-Line Fire Protection, LLC — free Get an email when a new federal OSHA severe-injury report for Front-Line Fire Protection, LLC is published. One employer, no account, unsubscribe in one click.
Site address
376 3RD STREET
City
EVERETT
State
MA
ZIP
02149
Mailing
325 NORTH MAIN STREET UNIT C, MIDDLETON, MA 01949
Inspection type
Unprogrammed Related (G)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
2
Ownership type
A

2 citations on file for this inspection.

1926.25 A

Deleted Serious Gravity 10 1 instance 3 exposed
Issued
Jun 26, 2025
Penalty
Initial $6,620 · Current $0 Reduced
29 CFR 1926.25(a): During the course of construction, alteration, or repairs, form and scrap lumber with protruding nails, and all other debris, was not kept clear from work areas, passageways, and stairs, in and around buildings or other structures.  Location: Job site;  On or about 04/30/2025, employees were exposed to trip and fall hazards while walking and working in areas and passageways of the job site where excess amounts of construction debris, scrap lumber with protruding nails, and  electrical extension cords and wiring were allowed to accumulate and obstruct paths of travel.
Recent events (2)
  • — I (S) $0
  • — Z (S) $6620

1926.100 A

Serious Gravity 10 1 instance 3 exposed
Issued
Jun 26, 2025
Penalty
Initial $6,620 · Current $4,634 Reduced
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets.  Location: Job site;  On or about 04/30/2025, employees were observed working in a hazardous area beneath an active framing and fire suppression system installation operation without he use of hardhats.