Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GC FODERA CONTRACTING, INC.

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of GC FODERA CONTRACTING, INC. in 376 3RD STREET, EVERETT, MA 02149 (NAICS 238990). OSHA activity number 348220401.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch GC Fodera Contracting, INC. — free Get an email when a new federal OSHA severe-injury report for GC Fodera Contracting, INC. is published. One employer, no account, unsubscribe in one click.
Site address
376 3RD STREET
City
EVERETT
State
MA
ZIP
02149
Mailing
4 MONTVALE AVE, WOBURN, MA 01801
Inspection type
Unprogrammed Related (G)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238990
Employees
5
Ownership type
A

8 citations on file for this inspection.

1910.134 D01 III

Serious Gravity 10 1 instance 3 exposed
Issued
Jul 8, 2025
Abate by
Sep 9, 2025
Penalty
Initial $11,585 · Current $5,793 Reduced
29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form.  Location: Job site;  On or about 05/01/2025, employees were allowed to utilize Sure Klean Vana Trol, a corrosive liquid consisting of Hydrochloric and Hydroxyacetic Acid, without the employer having first identified or evaluated the respiratory hazard(s) posed by utilizing this chemical substance.
Recent events (2)
  • — I (S) $5792.5
  • — Z (S) $11585

1910.1200 E01

Serious Gravity 10 1 instance 4 exposed
Issued
Jul 8, 2025
Abate by
Sep 9, 2025
Penalty
Initial $11,585 · Current $0 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met.  Location: Job site;  On or about 05/01/2025, the employer allowed employees to utilize Sure Klean Vana Trol, a corrosive liquid consisting of Hydrochloric and Hydroxyacetic Acid which requires the use of respiratory protection, and to conduct masonry brick cutting activities which could require the use of respiratory protection without having established and implemented a written hazard communication program which describes
Recent events (2)
  • — I (S) $0
  • — Z (S) $11585

1926.50 G

Serious Gravity 10 1 instance 3 exposed
Issued
Jul 8, 2025
Penalty
Initial $11,585 · Current $0 Reduced
29 CFR 1926.50(g): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use.  Location: Job site;  On or about 05/01/2025, employees were allowed to use Sure Klean Vana Trol, a corrosive liquid consisting of Hydrochloric and Hydroxyacetic Acid, without eyewash stations, bottles, or other quick drenching or flushing facilities within the working area for immediate emergency use.
Recent events (2)
  • — I (S) $0
  • — Z (S) $11585

1926.1153 G01

Serious Gravity 10 1 instance 4 exposed
Issued
Jul 8, 2025
Abate by
Sep 9, 2025
Penalty
Initial $11,585 · Current $0 Reduced
29 CFR 1926.1153(g)(1): The employer did not establish and implement a written silica exposure control plan.   Location: Job site;  On or about 05/01/2025, employees are allowed to conduct work which could expose them to respirable crystalline silica without an established and implemented written silica exposure plan.
Recent events (2)
  • — I (S) $0
  • — Z (S) $11585

1926.102 A01

Serious Gravity 10 1 instance 3 exposed
Issued
Jul 8, 2025
Penalty
Initial $11,585 · Current $5,793 Reduced
29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.  Location: Job site;  On or about 05/01/2025, employees were observed utilizing Sure Klean Vana Trol, a corrosive liquid consisting of Hydrochloric and Hydroxyacetic Acid, in 5-gallon buckets to clean masonry bricks without the use of eye and face protection.
Recent events (2)
  • — I (S) $5792.5
  • — Z (S) $11585

1926.451 F07

Serious Gravity 10 1 instance 4 exposed
Issued
Jul 8, 2025
Abate by
Sep 9, 2025
Penalty
Initial $11,585 · Current $5,793 Reduced
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees selected by, and under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration.  Location: Job site;  On or about 04/30/2025, employer allowed the utilization and operation of  Hydro-Mobile scaffolding systems which were not correctly erected per the manufacturer instructions and training for safe utilization/operation of the system and was not identified or corrected by a competent person prior to their usage.
Recent events (2)
  • — I (S) $5792.5
  • — Z (S) $11585

1926.451 F06

Serious Gravity 10 1 instance 3 exposed
Issued
Jul 8, 2025
Penalty
Initial $0 · Current $0
29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6).Note:  Specify distances as indicated in table in paragraph (f)(6) of this section.  Location: Job site;  On or about 04/30/2025, employees were exposed to the overhead live electrical service drop which was entering the building from the utility pole which was within 10-feet of the employees working from the Hydro-Mobile scaffolding erected beneath the service drop. The electrical line was tested by the town electrical inspector on 05/01/2025 and was confirmed to be live to the building but had not been turned on at the meter.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B09 I

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 8, 2025
Penalty
Initial $9,931 · Current $0 Reduced
29 CFR 1926.501(b)(9)(i): Each employee performing overhand bricklaying and related work 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a controlled access zone.  Location: Job site;  On or about 05/01/2025, employees were observed cleaning red masonry bricks with Sure Klean Vana Trol and other masonry bricklaying activities on the lower roof of the multi-family residential building from approximately 7-feet above the ground below who were not protected from falling by use of guardrails, safety nets, personal fall arrest systems, or a controlled access zone.
Recent events (2)
  • — I (S) $0
  • — Z (S) $9931

View GC Fodera Contracting, INC.'s full OSHA safety record →