WINNETKA, IL —
OSHA Inspection: A. LAMP CONCRETE CONTRACTORS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of A. LAMP CONCRETE CONTRACTORS, INC. in TOWER RD & FOXDALE AVE TO ELDORADO ST & FOXDALE AVE, WINNETKA, IL 60093 (NAICS 237310). OSHA activity number 348220534.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- A. LAMP CONCRETE CONTRACTORS, INC.
- Site address
- TOWER RD & FOXDALE AVE TO ELDORADO ST & FOXDALE AVE
- City
- WINNETKA
- State
- IL
- ZIP
- 60093
- Mailing
- 1900 WRIGHT BLVD., SCHAUMBURG, IL 60193
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237310
- Employees
- 149
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.651 I03
- Issued
- Sep 30, 2025
- Penalty
- Initial $15,322 · Current $15,322
General-duty citation text
29 CFR 1926.651(i)(3): Sidewalks, pavements, or appurtenant structures had been undermined and a support system or another method was not provided to protect employees from the possible collapse of such structures: a) On May 2, 2025, at the Foxdale Water Main Project in Winnetka, Illinois, employees were exposed to pavement collapse while walking on pavement above and performing work in an excavation under areas of pavement that had been undermined. No abatement certification or documentation is required for this item.
Recent events (2)
- — C (S) $15322
- — Z (S) $15322
1926.652 G01 II
- Issued
- Sep 30, 2025
- Abate by
- Oct 27, 2025
- Penalty
- Initial $16,550 · Current $16,550
General-duty citation text
29 CFR 1926.652(g)(1)(ii): Shields were not installed in a manner to restrict lateral or other hazardous movement of the shield in the event of the application of sudden lateral loads: a) On or about April 24, 2025, at the Foxdale Ave. Water Main Project in Winnetka, Illinois, the employer did not ensure that shields, such as the Build-A-Box Modular Trench Shield BAB-4 and the Build-A-Box Modular Trench Shield BAB-6, were installed to restrict movement in the event of sudden movement. The boxes occupied by employees were not secured to prevent movement during an unexpected event causing lateral loads. b) On May 2, 2025, at the Foxdale Ave. Water Main Project in Winnetka, Illinois, the employer did not ensure that shields, such as the Build-A-Box Modular Trench Shield BAB-4 and the Build-A-Box Modular Trench Shield BAB-6, were installed to restrict movement in the event of sudden movement. The boxes occupied by employees were not secured to prevent movement during an unexpected event causing lateral loads. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — C (S) $16550
- — Z (S) $16550
1926.652 G02
- Issued
- Sep 30, 2025
- Abate by
- Oct 27, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.652(g)(2): Excavations of earth material to a level no greater than 2 feet (.61m) below the bottom of a shield was permitted: a) On or about April 24, 2025, at the Foxdale Ave. Water Main Project in Winnetka, Illinois, employees were permitted to enter an excavation and perform work where the earth material was excavated approximately four feet below the bottom of the support system, Build-A-Box BAB-4 Modular Trench Shield. b) On or about May 1, 2025, at the Foxdale Ave. Water Main Project in Winnetka, Illinois, employees were permitted to enter an excavation and perform work where the earth material was excavated approximately three feet and nine inches below the bottom of the support system, Pro-Tec Trench Shield, Serial #35715. c) On May 2, 2025, the Foxdale Ave. Water Main Project in Winnetka, Illinois, employees were permitted to enter an excavation and perform work where the earth material was excavated approximately seven feet six inches on the north wall, four feet six inches on the east wall, and six feet five inches on the south wall, below the bottom of the support system, Build-A-Box BAB-4 Modular Trench Shield. d) On May 2, 2025, the Foxdale Ave. Water Main Project in Winnetka, Illinois, employees were permitted to enter an excavation and perform work where the earth material was excavated approximately four feet six below the bottom of the support system, the Build-A-Box BAB-6 Modular Trench Shield. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — C (S) $0
- — Z (S) $0
1926.652 A01
- Issued
- Sep 30, 2025
- Abate by
- Oct 27, 2025
- Penalty
- Initial $165,514 · Current $165,514
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c). a) On or about April 23, 2025, at the Foxdale Ave. Water Main Project in Winnetka, Illinois, an employee was exposed to cave-in hazards while performing work in an unprotected excavation of approximately six feet in depth. The employer did not ensure the employee was protected from cave-in hazards. b) On or about April 24, 2025, at the Foxdale Ave. Water Main Project in Winnetka, Illinois, employees were exposed to cave-in hazards while performing work in an unprotected excavation of approximately seven feet six inches in depth. The employer did not ensure that employees were protected from cave-in hazards. c) On or about April 25, 2025, at the Foxdale Ave. Water Main Project in Winnetka, Illinois, an employee was exposed to cave-in hazards while performing work in an unprotected excavation of approximately six feet six inches in depth. The employer did not ensure the employee was protected from cave-in hazards. d) On or about April 25, 2025, at the Foxdale Ave. Water Main Project in Winnetka, Illinois, employees were exposed to cave-in hazards while performing work in an unprotected excavation of approximately six feet in depth. The employer did not ensure that employees were protected from cave-in hazards. e) On or about April 28, 2025, at the Foxdale Ave. Water Main Project in Winnetka, Illinois, employees were exposed to cave-in hazards while performing work in an unprotected excavation of approximately six feet six inches in depth. The employer did not ensure that employees were protected from cave-in hazards. f) On May 2, 2025, at the Foxdale Ave. Water Main Project in Winnetka, Illinois, an employee was exposed to cave-in hazards while performing work in an unprotected excavation of approximately eight feet six inches in depth in the south excavation for the setting of the manhole. The employer did not ensure the employee was protected from cave-in hazards. g) On or about May 2, 2025, at the Foxdale Ave. Water Main Project in Winnetka, Illinois, an employee was exposed to cave-in hazards while performing work in an unprotected excavation of approximately nine feet seven inches in depth in the east excavation for the setting of the fire hydrant. The employer did not ensure the employee was protected from cave-in hazards. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — C (W) $165514
- — Z (W) $165514
1926.651 C02
- Issued
- Sep 30, 2025
- Abate by
- Oct 27, 2025
- Penalty
- Initial $35,748 · Current $35,748
General-duty citation text
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: a) On or about April 23, 2025, at the Foxdale Ave. Water Main Project in Winnetka, employees working in an excavation, of up to approximately six feet three inches in depth, were not provided with a suitable means of egress. b) On or about April 28, 2025, at the Foxdale Ave. Water Main Project in Winnetka, employees working in an excavation, of up to approximately six feet in depth, were not provided with a suitable means of egress. c) On or about April 29, 2025, at the Foxdale Ave. Water Main Project in Winnetka, employees working in an excavation, of up to approximately six feet six inches in depth, were not provided with a suitable means of egress. A. Lamp Concrete Contractors, Inc. was previously cited for a violation of this occupational safety and health standard 29CFR 1926.651(c)(2), which was contained in OSHA inspection number 1605465, citation number 1, item number 1 and was affirmed as a final order on October 25, 2023, with respect to a workplace located at 23rd Avenue & Roosevelt Road in Broadview, Illinois. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — C (R) $35748
- — Z (R) $35748
1926.652 C02 I
- Issued
- Sep 30, 2025
- Abate by
- Oct 27, 2025
- Penalty
- Initial $5,106 · Current $5,106
General-duty citation text
29 CFR 1926.652(c)(2)(i): Design of support systems, shield systems, or other protective systems that are drawn from manufacturer's tabulated data were not in accordance with all specifications, recommendations, and limitations issued or made by the manufacturer: a) On or about April 24, 2025, at the Foxdale Ave. Water Main Project in Winnetka, employees in excavations were not provided with adequate cave-in protection as the protective system that was being utilized was not in accordance with all specifications. The Build-A-Box BAB-4 in the east end of the excavation, was not supplied with an adequate number of pins per panel, not backfilled, not within two feet of the bottom of the excavation due to extension of all adjustable legs and missing panels, and had damage to the northeast corner post. b) On or about April 24, 2025, at the Foxdale Ave. Water Main Project in Winnetka, employees in excavations were not provided with adequate cave-in protection as the protective system that was being utilized was not in accordance with all specifications. The Build-A-Box BAB-6 in the middle of the excavation, was not supplied with an adequate number of pins per panel, not backfilled, not within two feet of the bottom of the excavation due to extension of all adjustable legs and missing panels, and the bottom of the corner posts were not secured to the bottom hole of the extended legs. c) On or about May 2, 2025, at the Foxdale Ave. Water Main Project in Winnetka, employees in excavations were not provided with adequate cave-in protection as the protective system that was being utilized was not in accordance with all specifications. The Build-A-Box BAB-4 in the east excavation, was not supplied with an adequate number of pins per panel, not backfilled, and was not within two feet of the bottom of the excavation due to extension of all adjustable legs and missing panels and the way it was positioned within the excavation. d) On or about May 2, 2025, at the Foxdale Ave. Water Main Project in Winnetka, employees in excavations were not provided with adequate cave-in protection as the protective system that was being utilized was not in accordance with all specifications. The Build-A-Box BAB-6 in the south end of the excavation, was not supplied with an adequate number of pins per panel, not backfilled, improperly lifted and moved, and the bottom of the corner posts were not secured to all of the extended legs. A. Lamp Concrete Contractors, Inc. was previously cited for a violation of this occupational safety and health standard 29CFR 1926.652(c)(2)(i), which was contained in OSHA inspection number 1605465, citation number 3, item number 1 and was affirmed as a final order on October 25, 2023, with respect to a workplace located at 23rd Avenue & Roosevelt Road in Broadview, Illinois. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — C (R) $5106
- — Z (R) $5106
1904.40 A
- Issued
- Sep 30, 2025
- Abate by
- Oct 27, 2025
- Penalty
- Initial $2,553 · Current $2,553
General-duty citation text
29 CFR 1904.40(a): The employer did not provide an authorized government representative the records within four business hours. a) On May 14, 2025, the employer failed to provide the requested OSHA 300 logs or an equivalent form within four business hours of their request for the year 2025. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — C (O) $2553
- — Z (O) $2553
More inspections at A. Lamp Concrete Contractors, INC.
View A. Lamp Concrete Contractors, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 237310)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348220534.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.