YORK, PA ·
OSHA Inspection: SOLORIO CONTRACTING
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SOLORIO CONTRACTING in 1661 WEST KING STREET, YORK, PA 17404 (NAICS 238160). OSHA activity number 348220567.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SOLORIO CONTRACTING
- Site address
- 1661 WEST KING STREET
- City
- YORK
- State
- PA
- ZIP
- 17404
- Mailing
- 1628 WEST MARKET STREET, YORK, PA 17404
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 6
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1926.501 B04 I
- Issued
- Jun 10, 2025
- Abate by
- Jul 8, 2025
- Penalty
- Initial $4,965 · Current $4,965
General-duty citation text
29 CFR 1926.501(b)(4)(i):Each employee on walking/working surfaces was not protected from falling through holes (including skylights), more than six feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes. a) 1661 West King Street York, PA - On or about May 2, 2025, employees were working on a roof with an unguarded hole approximately 20 feet above the lower level without utilizing any means of fall protection. Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (1)
- · Z (S) $4965
1926.501 B10
- Issued
- Jun 10, 2025
- Abate by
- Jul 8, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest system: a) 1661 West King Street York, PA - On or about May 2, 2025, employees were observed replacing skylights on a low-sloped commercial building roof without the benefit of a fall protection system, exposing them to a fall of approximately 20 feet. Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (1)
- · Z (S) $0
1926.502 F01 III
- Issued
- Jun 10, 2025
- Abate by
- Jul 8, 2025
- Penalty
- Initial $4,965 · Current $4,965
General-duty citation text
29 CFR 1926.502(f)(1)(iii):Points of access, material handling areas, storage areas, and/or hoisting areas were not connected to the work area by an access path formed by two warning lines: a) 1661 West King Street York, PA - On or about May 2, 2025, at the ladder access to the roof on the Northeast corner, employees replacing skylights on a low-sloped commercial building roof were exposed to a fall hazard of approximately 20 feet to the ground below, a warning line system was not erected to connect the point of access to the work area. Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (1)
- · Z (S) $4965
More inspections in this industry (NAICS 238160)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 348220567.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.