EVERETT, MA ·
OSHA Inspection: COTTA CONSTRUCTION INC
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of COTTA CONSTRUCTION INC in 376 3RD STREET, EVERETT, MA 02149 (NAICS 238130). OSHA activity number 348220666.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COTTA CONSTRUCTION INC
- Site address
- 376 3RD STREET
- City
- EVERETT
- State
- MA
- ZIP
- 02149
- Mailing
- 69 FOX STREET, WORCESTER, MA 01604
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 8
- Ownership type
- Private (A)
Citations
9 citations on file for this inspection.
1926.25 A
- Issued
- Jun 27, 2025
- Penalty
- Initial $4,965 · Current $4,965
General-duty citation text
29 CFR 1926.25(a): During the course of construction, alteration, or repairs, form and scrap lumber with protruding nails, and all other debris, was not kept clear from work areas, passageways, and stairs, in and around buildings or other structures. Location: Job site; On or about 04/30/2025, employees were exposed to trip and fall hazards while walking and working in areas and passageways of the job site where excess amounts of construction debris, scrap lumber with protruding nails, and electrical extension cords and wiring were allowed to accumulate and obstruct paths of travel.
Recent events (3)
- · A (S) $4965
- · I (S) $2482.5
- · Z (S) $4965
1926.34 A
- Issued
- Jun 27, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.34(a): Building or structure exits were not so arranged and maintained as to provide free and unobstructed egress from all parts of the building or structure at all times when it was occupied. Location: Job site; On or about 04/30/2025, employees were allowed to work inside the multi-family building under construction at the job site which had exits and egress routes which were obstructed by building debris, scrap material, electrical extension cords or temporary wiring, or were multiple feet above the ground below and were only accessible by a job-made ladder which had 3 unevenly spaced rungs which was not secured from falling and fed into the beginnings of a deck frame which employees would need to duck under or hurdle over to egress the immediate vicinity of the building.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.34 B
- Issued
- Jun 27, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.34(b): Exits and access to exits were not marked by a readily visible sign. Location: Job site; On or about 04/30/2025, employees were allowed to work in a multi-family building under construction which did not have readily visible exit markings or signage at exits or exit accessways.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.56 A
- Issued
- Jun 27, 2025
- Penalty
- Initial $4,965 · Current $4,965
General-duty citation text
29 CFR 1926.56(a): While work was in progress, construction areas, ramps, runways, corridors, offices, shops or storage areas were not lighted to the minimum illumination intensities as listed in Table D-3 of 29 CFR 1926.56:(a). Location: Job site; On or about 04/30/2025, employees were allowed to work in construction areas, corridors, and stairwells which were not lighted to the minimum illumination intensities as listed in Table D-3 of 29 CFR 1926.56(a), and in some cases were pitch black: a) In general construction areas around the job site where the requirement is 5 foot-candles. b) Indoor corridors, hallways, and exit ways where the requirement is 5 foot-candles.
Recent events (3)
- · A (S) $4965
- · I (S) $0
- · Z (S) $4965
1926.100 A
- Issued
- Jun 27, 2025
- Penalty
- Initial $4,965 · Current $4,965
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets. Location: Job site; On or about 04/30/2025, employees were observed working in a hazardous area beneath an active framing and fire suppression system installation operation without he use of hardhats.
Recent events (3)
- · A (S) $4965
- · I (S) $2482.5
- · Z (S) $4965
1926.102 A01
- Issued
- Jun 27, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying objects while using a nail gun. Location: Job site; On or about 04/30/2025, employees were allowed to utilize pneumatic nail guns without proper eye/face protection to protect against potential flying objects while performing framing activities on the job site.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.501 A02
- Issued
- Jun 27, 2025
- Penalty
- Initial $4,965 · Current $4,965
General-duty citation text
29 CFR 1926.501(a)(2): The employer did not determine if the walking/working surfaces on which its employees were to work had the strength and structural integrity to support employees safely. Location: Job site; On or about 04/30/2025, an employee was allowed to conduct framing activities from atop a stack of Mr. Cool Advantage 9K Heat Pump Air Conditioner Split Type boxes which were not evaluated for the strength or structural integrity to support the employee(s) safely.
Recent events (3)
- · A (S) $4965
- · I (S) $2482.5
- · Z (S) $4965
1926.501 B04 II
- Issued
- Jun 27, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.501(b)(4)(ii): Each employee on a walking/working surface was not protected from tripping in or stepping into or through holes by covers. Location: Job site; On or about 04/30/2025, employees were allowed to walk and work in the vicinity of numerous floor holes which were located throughout the building in new multi-family housing units and main passageway and corridors that employees were regularly walking and working within.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.1052 C01 II
- Issued
- Jun 27, 2025
- Penalty
- Initial $4,965 · Current $4,965
General-duty citation text
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76cm) whichever is less were not equipped with one stair rail system along each unprotected side or edge. Location: Job site; On or about 04/30/2025, employees were allowed to utilize a main stairway to transit the different floors and egress ways of the building under construction which, where the stairway was not equipped with a stair rail system along each unprotected side or edge.
Recent events (3)
- · A (S) $4965
- · I (S) $2482.5
- · Z (S) $4965
More inspections in this industry (NAICS 238130)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 348220666.