PORTLAND, ME —
OSHA Inspection: JOHNSON AND JORDAN
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of JOHNSON AND JORDAN in 331 VERANDA STREET, PORTLAND, ME 04070 (NAICS 238220). OSHA activity number 348227372.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- JOHNSON AND JORDAN
- Site address
- 331 VERANDA STREET
- City
- PORTLAND
- State
- ME
- ZIP
- 04070
- Mailing
- 18 MUSSEY ROAD, SCARBOROUGH, ME 04070
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238220
- Employees
- 200
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C07 I
- Issued
- May 9, 2025
- Abate by
- Jun 27, 2025
- Penalty
- Initial $16,550 · Current $16,550
General-duty citation text
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that the purpose and function of the energy control program was understood by employees: Establishment - Employer failed to provide adequate lockout tagout training to ensure three employees understood the requirements and need for the hazardous energy control program. Failure to provide the training resulted in fingertip amputations while an employee was servicing a commercial air handler.
Recent events (2)
- — I (O) $16550
- — Z (S) $16550
1910.147 D02
- Issued
- May 9, 2025
- Penalty
- Initial $16,550 · Current $16,550
General-duty citation text
29 CFR 1910.147(d)(2): An orderly shutdown of the machine or equipment was not utilized to avoid any additional or increased hazards to employees as a result of equipment stoppage: Rooftop - Employer failed to ensure employees understood and utilized an orderly shutdown of a commercial air handler, resulting in an employee contacting a moving belt, amputating two fingertips.
Recent events (2)
- — I (O) $16550
- — Z (S) $16550
1910.28 B13 III A
- Issued
- May 9, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.28(b)(13)(iii)(A): When work is performed 15 feet or more from the roof edge, the employer did not protect each employee from falling by a guardrail system, safety net system, travel restraint system, or personal fall arrest system or a designated area: Rooftop - Employer allowed three employees to access a third-story flat roof without a guardrail system, safety net system, travel restraint system, or personal fall arrest system, or a designated area.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Johnson and Jordan
View Johnson and Jordan's full OSHA safety record →
More inspections in this industry (NAICS 238220)
More inspections in ME
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348227372.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.