CAPE CORAL, FL —
OSHA Inspection: BADILLO ENTERPRISES OF SW FLORIDA INC
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of BADILLO ENTERPRISES OF SW FLORIDA INC in 5352 BAYSIDE CT., CAPE CORAL, FL 33904 (NAICS 238140). OSHA activity number 348227430.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BADILLO ENTERPRISES OF SW FLORIDA INC
- Site address
- 5352 BAYSIDE CT.
- City
- CAPE CORAL
- State
- FL
- ZIP
- 33904
- Mailing
- 10131 CAROLINA ST, BONITA SPRINGS, FL 34135
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 4
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.451 B01
- Issued
- Jul 16, 2025
- Abate by
- Aug 4, 2025
- Penalty
- Initial $4,965 · Current $2,979 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) a) On or about May 5, 2025, at worksite: Employer failed to ensure that employees were protected from falling in that the section of the scaffold that the employees were working on only had approximately 2 (9 in wide) planks on the scaffold that was approximately 5 ft wide between the front and rear upright exposing employees to falls hazards of 14 ft 4 in.
Recent events (2)
- — I (S) $2979
- — Z (S) $4965
1926.451 B04
- Issued
- Jul 16, 2025
- Abate by
- Aug 4, 2025
- Penalty
- Initial $4,965 · Current $2,979 Reduced
General-duty citation text
29 CFR 1926.451(b)(4):Each end of a platform, not cleated or otherwise restrained by hooks or equivalent means, did not extend over the centerline of its support at least 6 inches (15 cm) a) On or about May 5, 2025, at worksite: Employer failed to ensure that the wooden planks stayed even on the scaffolds maintaining 6 inches past the support, exposing employees to fall hazards of approximately 14 ft 4 in.
Recent events (2)
- — I (S) $2979
- — Z (S) $4965
1926.451 C02
- Issued
- Jul 16, 2025
- Abate by
- Aug 4, 2025
- Penalty
- Initial $4,965 · Current $2,979 Reduced
General-duty citation text
29 CFR 1926.451(c)(2):Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates and mud sills or other adequate firm foundation: a) On or about May 5, 2025, at worksite: Employer failed to ensure that the base plates were set up on mud sills or other adequate foundation by putting the baseplates directly into the dirt, exposing employees to fall hazards of approximately 14 ft 4 in.
Recent events (2)
- — I (S) $2979
- — Z (S) $4965
1926.451 E01
- Issued
- Jul 16, 2025
- Abate by
- Aug 4, 2025
- Penalty
- Initial $3,547 · Current $2,128 Reduced
General-duty citation text
29 CFR 1926.451(e)(1):When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. a) On or about May 5, 2025, at worksite: Employer failed to ensure that employees had safe access to the scaffold in that they allowed the employees to climb the uprights of the scaffold for access and egress to the working surface.
Recent events (2)
- — I (S) $2128.2
- — Z (S) $3547
1926.451 G01
- Issued
- Jul 16, 2025
- Abate by
- Aug 4, 2025
- Penalty
- Initial $33,103 · Current $19,862 Reduced
General-duty citation text
29 CFR 1926.451(g)(1):Each employee on a scaffold more than 10 feet above a lower level was not protected from falling to that lower level. a) On or about May 5, 2025, at worksite: Employer failed to ensure that employees were protected from falling to the next lower level in that the scaffold did not did not have top and mid rails installed exposing employees to fall hazards of approximately 14 ft 4 in above the next lower level.
Recent events (2)
- — I (W) $19861.8
- — Z (W) $33103