CRESSONA, PA —
OSHA Inspection: HYDRO EXTRUSION USA LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of HYDRO EXTRUSION USA LLC in 53 POTTSVILLE STREET, CRESSONA, PA 17929 (NAICS 331313). OSHA activity number 348227695.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HYDRO EXTRUSION USA LLC
- Site address
- 53 POTTSVILLE STREET
- City
- CRESSONA
- State
- PA
- ZIP
- 17929
- Mailing
- 53 POTTSVILLE STREET, CRESSONA, PA 17929
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331313
- Employees
- 1150
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C07 III A
- Issued
- Aug 4, 2025
- Abate by
- Aug 25, 2025
- Penalty
- Initial $13,240 · Current $13,240
General-duty citation text
29 CFR 1910.147(c)(7)(iii)(A):Retraining was not provided for authorized and affected employees when there was a change in their job assignments, a change in machines, equipment or processes that presented a new hazard, or when there was a change in the energy control procedures: a) P16 Extrusion Press- On or about May 1, 2025, the employer did not provide retraining to authorized employees following a change to equipment that altered the stored hydraulic energy in the Butt Shear Cylinders of the P16 Extrusion Press. As a result, employees were exposed to an amputation hazard
Recent events (2)
- — I (S) $13240
- — Z (S) $13240
1910.147 C04 II
- Issued
- Jul 9, 2025
- Abate by
- Aug 4, 2025
- Penalty
- Initial $16,550 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items of this section: a) P16 Extrusion Press- On or about May 5, 2025, employees were exposed to amputation hazards due to the P16 LTV Procedure not providing guidance for control of hydraulic energy sources. ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $16550
1910.147 D05 I
- Issued
- Jul 9, 2025
- Abate by
- Aug 4, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(5)(i): All potentially hazardous stored or residual energy was not relieved, disconnected, restrained or otherwise rendered safe after the application of lockout or tagout devices to energy isolating devices: a) P16 Extrusion Press- On or about May 5, 2025, employees were exposed to amputation hazards due to not controlling hydraulic energy sources while attempting replacing packing on a hydraulic cylinder. ABATMENT CERTIFICATION AND DOCUMENTATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Hydro Extrusion USA LLC
View Hydro Extrusion USA LLC's full OSHA safety record →
More inspections in this industry (NAICS 331313)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348227695.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.