STERLING, MA ·
OSHA Inspection: LEE PLASTICS INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of LEE PLASTICS INC. in 102 PRATTS JUNCTION ROAD, STERLING, MA 01564 (NAICS 326199). OSHA activity number 348232117.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LEE PLASTICS INC.
- Site address
- 102 PRATTS JUNCTION ROAD
- City
- STERLING
- State
- MA
- ZIP
- 01564
- Mailing
- 102 PRATTS JUNCTION ROAD, STERLING, MA 01564
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 21
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1910.147 C01
- Issued
- May 22, 2025
- Abate by
- Jul 11, 2025
- Penalty
- Initial $4,729 · Current $3,310 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer had not established a program consisting of an energy control procedure, employee training, and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: 102 Pratts Junction Road, Sterling, MA: On and before May 8, 2025, the employer had not established an energy control program to protect employees and outside contractors who performed maintenance and servicing activities on the Milacron injection molding machines and other multi-energy source machines. *Abatement Notes: Energy control procedures are required to be documented for all multiple-energy source machines. Documented energy control procedures are not required for hardwired single energy source machines such as the Wittmann robots, but the employer must ensure they are isolated, locked out, and verified as isolated during servicing. Energy control training is required to be documented and provided to ensure that the purpose and function of the energy control program are understood by employees. Employer must ensure that authorized employees acquire the knowledge and skills required for the safe application, usage, and removal of the energy controls to protect themselves and outside contractors. Periodic inspections are required for documented energy control procedures and shall include the following elements: - Appointment of an authorized employee to inspect each local procedure for inaccuracies during an energy control task - A review by inspector with each authorized employee, of that employee's responsibilities under each energy control procedure they are authorized to use - Certification that the periodic inspections have been performed by identifying the machines or equipment on which the energy control procedures were being utilized, the dates of the inspections, the employees included in the inspections, and the persons performing the inspections *Abatement notes are intended only to provide clarity regarding existing requirements under the law or agency policies. Abatement notes do not create (or diminish) legal obligations under the Occupational Safety and Health Act.
Recent events (2)
- · I (S) $3310.3
- · Z (S) $4729
1904.41 A01 I
- Issued
- May 22, 2025
- Abate by
- Jul 11, 2025
- Penalty
- Initial $946 · Current $662 Reduced
General-duty citation text
29 CFR 1904.41(a)(1)(i): The establishment had 20 or more employees but fewer than 250 employees during the previous calendar year, the establishment was classified in an industry listed in appendix A to subpart E of this part, and the employer did not electronically submit information from OSHA Form 300A Summary of Work-Related Injuries and Illnesses to OSHA or OSHA's designee by the specified date: 102 Pratts Junction Road, Sterling, MA: As of May 8, 2025, the employer had not electronically submitted the information from their 2024 OSHA Form 300A. The employer's 2024 OSHA 300A for this establishment listed 21 employees and a North American Industry Classification System code of 326199-All Other Plastics Product Manufacturing.
Recent events (2)
- · I (O) $662.2
- · Z (O) $946
More inspections at LEE Plastics INC.
View LEE Plastics INC.'s full OSHA safety record →
More inspections in this industry (NAICS 326199)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 348232117.