CONCORD, NH —
OSHA Inspection: QUALITY GRANITE AND CABINETRY, LLC
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of QUALITY GRANITE AND CABINETRY, LLC in 78 REGIONAL DR., CONCORD, NH 03301 (NAICS 327991). OSHA activity number 348235243.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- QUALITY GRANITE AND CABINETRY, LLC
- Site address
- 78 REGIONAL DR.
- City
- CONCORD
- State
- NH
- ZIP
- 03301
- Mailing
- 78 REGIONAL DR., CONCORD, NH 03301
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327991
- Employees
- 16
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.176 B
- Issued
- Jun 11, 2025
- Abate by
- Jul 30, 2025
- Penalty
- Initial $3,547 · Current $1,774 Reduced
General-duty citation text
29 CFR 1910.176(b): Storage of material created a hazard: Site - On or about 5/8/2025, The employer did not ensure granite slabs weighing up to 1,200 pounds were stored in a way to prevent sliding or collapse.
Recent events (2)
- — I (S) $1773.5
- — Z (S) $3547
1910.178 A04
- Issued
- Jun 11, 2025
- Abate by
- Jul 30, 2025
- Penalty
- Initial $3,547 · Current $1,774 Reduced
General-duty citation text
29 CFR 1910.178(a)(4):Modifications and additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval: Shop area - On or about 5/8/2025, the employer did not ensure a boom attachment used on a Hyster H50UT forklift to hoist granite slabs weighing up to 1,200 lbs. was approved by the manufacturer.
Recent events (2)
- — I (S) $1773.5
- — Z (S) $3547
1910.178 A05
- Issued
- Jun 11, 2025
- Abate by
- Jul 30, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(a)(5): The powered industrial truck was equipped with front-end attachments other than factory installed attachments, however the employer did not request that the truck be marked to identify the attachments and show the approximate weight of the truck and attachment combination at maximum elevation with load laterally centered: Shop area - On or about 5/8/2025, the employer did not ensure a Hyster H50UT forklift was marked to use a front-end boom attachment
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 L01 II
- Issued
- Jun 11, 2025
- Abate by
- Aug 20, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(1)(ii):The employer did not ensure that each operator had successfully completed the training required by paragraph (l), except as permitted by paragraph (l)(5), prior to permitting an employee to operate a powered industrial truck Shop - On or about 5/8/2025, the employer did not ensure employees operating a Hyster H50UT forklift had been trained to operate the lift.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.334 A04
- Issued
- Jun 11, 2025
- Penalty
- Initial $3,015 · Current $1,508 Reduced
General-duty citation text
29 CFR 1910.334(a)(4):Portable electric equipment and flexible cords that was used in highly conductive work locations (such as those inundated with water or other conductive locations) or in job locations where employees were likely to contact water or conductive liquids were not approved for those locations: Polishing area - On or about 5/8/2025, employees were exposed to an electrical shock hazard when using a Makita SJS2 hand held electric grinder for wet cutting granite.
Recent events (2)
- — I (S) $1508
- — Z (S) $3015
1910.305 B01 I
- Issued
- Jun 11, 2025
- Abate by
- Jul 30, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(i):Openings through which conductors entered cutout boxes, cabinets, or fittings were not effectively closed: Wall behind the wet saw - On or about 5/8/2025, the employer did not ensure an opening through a wall mounted electrical box was closed.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 327991)
More inspections in NH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348235243.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.