LEXINGTON, MA —
OSHA Inspection: M&A CONTRACTORS LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of M&A CONTRACTORS LLC in 3 FRANCES ROAD, LEXINGTON, MA 02421 (NAICS 236118). OSHA activity number 348236217.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- M&A CONTRACTORS LLC
- Site address
- 3 FRANCES ROAD
- City
- LEXINGTON
- State
- MA
- ZIP
- 02421
- Mailing
- 76 SUMMER STREET, NATICK, MA 01760
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236118
- Employees
- 4
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.451 G01
- Issued
- Jul 31, 2025
- Penalty
- Initial $0 · Current $3,000
General-duty citation text
29 CFR 1926.451(g)(1) - Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: Location - Building Exterior, Residential Construction Site On or about 05/09/2025, employees were exposed to fall hazards while utilizing a pump-jack scaffold at heights in excess of 10 feet without fall protection.
Recent events (3)
- — F (S) $3000
- — C (S) $0
- — Z (S) $0
1926.501 B13
- Issued
- Jul 31, 2025
- Penalty
- Initial $3,972 · Current $0 Reduced
General-duty citation text
29 CFR 1926.501(b)(13) - Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) Location - 2nd Floor Hallway, Residential Construction Site On or about 05/09/2025, employees were exposed to trip and fall hazards due to a hole in the 2nd floor subfloor not being covered. b) Location - Roof, Residential Construction Site On or about 05/09/2025, employees were exposed to fall hazards while accessing the roof from an adjacent scaffold at heights in excess of 10 feet without fall protective measures in place.
Recent events (3)
- — F (S) $0
- — C (S) $3972
- — Z (S) $3972
1926.20 B02
- Issued
- Jul 31, 2025
- Penalty
- Initial $3,972 · Current $1,000 Reduced
General-duty citation text
1926.20(b)(2): Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers. Location - Building Exterior, Residential Construction Site On or about 05/09/2025, the employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s).
Recent events (3)
- — F (O) $1000
- — C (S) $3972
- — Z (S) $3972
1926.452 J02
- Issued
- Jul 31, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.452(j)(2) - Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary: Location - Building Exterior, Residential Construction Site On or about 05/09/2025, a pump-jack scaffold was set up for use without appropriate levels of bracing exposing employees to fall hazards.
Recent events (3)
- — F (O) $0
- — C (S) $0
- — Z (S) $0
1926.1052 C01
- Issued
- Jul 31, 2025
- Penalty
- Initial $1,702 · Current $0 Reduced
General-duty citation text
29 CFR 1926.1052(c)(1) - Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail and one stair rail system along each unprotected side or edge: Location - Building Exterior, Residential Construction Site On or about 05/09/2025, employees were exposed to fall hazards from a stairway system leading from the ground level to the first floor portico without a railing installed.
Recent events (3)
- — F (O) $0
- — C (S) $1702
- — Z (S) $1702
More inspections in this industry (NAICS 236118)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348236217.