HAMILTON, OH —
OSHA Inspection: MITER MASONRY CONSTRUCTION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of MITER MASONRY CONSTRUCTION in 7215 GATEWAY AVE, HAMILTON, OH 45011 (NAICS 238140). OSHA activity number 348236407.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MITER MASONRY CONSTRUCTION
- Site address
- 7215 GATEWAY AVE
- City
- HAMILTON
- State
- OH
- ZIP
- 45011
- Mailing
- 421 MAPLE AVE, CINCINNATI, OH 45215
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 12
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 A01
- Issued
- Jun 23, 2025
- Penalty
- Initial $11,585 · Current $6,000 Reduced
General-duty citation text
29 CFR 1926.451(a)(1):Except as provided in paragraphs (a)(2), (a)(3), (a)(4), (a)(5) and (g) of this section, each scaffold and scaffold component shall be capable of supporting, without failure, its own weight and at least 4 times the maximum intended load applied or transmitted to it. a) On or about May 7, 2025, the employer failed to ensure that the Hydromobile scaffold components were capable of supporting at least four times the intended load in that; A foreman reconfigured walkboards to create a 90-degree turn using only one outrigger for support and fastened the boards with self-tapping screws. The assembly shifted when the foreman stepped on it, causing him to fall approximately 16 feet to the ground and sustain serious injuries.
Recent events (2)
- — I (S) $6000
- — Z (S) $11585
1926.451 A06
- Issued
- Jun 23, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(a)(6): Scaffolds shall be designed by a qualified person and shall be constructed and loaded in accordance with that design. Non-mandatory Appendix A to this subpart contains examples of criteria that will enable an employer to comply with paragraph (a) of this section. a) On or about May 7, 2025, the employer failed to ensure the Hydromobile scaffold system was constructed in accordance with the manufacturer's design specifications. Specifically, a bearing bridge platform was assembled at a 90-degree inside corner using only one outrigger instead of the required two outriggers, as specified in the manufacturer's manual. The planks were secured to the outrigger with screws without using the required tube and clamp arrangement or additional support components such as knuckles. When an employee stepped onto the platform, the assembly shifted, resulting in a fall of approximately 16 feet.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 B08
- Issued
- Jun 23, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(b)(8): At all points of a scaffold where the platform changes direction, such as turning a corner, any platform that rests on a bearer at an angle other than a right angle shall be laid first, and platforms which rest at right angles over the same bearer shall be laid second, on top of the first platform. a) On or about May 7, 2025, the employer did not ensure that all points of the Hydromobile scaffold system where the platform changed direction had the angled planks laid first to prevent the planks from shifting under a load. As a result, an employee fell approximately 16 feet when the angled planks turned up under the load.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 F03
- Issued
- Jun 23, 2025
- Abate by
- Jul 28, 2025
- Penalty
- Initial $11,585 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(f)(3):Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity. a) On or about May 7, 2025, the employer did not ensure the Hydromobile scaffolding system scaffolding components were inspected for visible defects by a designated competent person before each work shift in that a platform modification was made at a 90-degree inside corner using only one outrigger instead of the two required by the manufacturer, and diagonal planks were installed improperly without following the required sequencing or structural supports. The configuration deviated from the scaffold design specified in the manufacturer's manual. As a result, an employee fell approximately 16 feet when the unsupported planks shifted under load, leading to serious injuries
Recent events (2)
- — I (S) $0
- — Z (S) $11585
More inspections in this industry (NAICS 238140)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348236407.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.