Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FAST LANE CONSTRUCTION LLC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of FAST LANE CONSTRUCTION LLC. in 8573 CINCINNATI-DAYTON RD, WEST CHESTER, OH 45069 (NAICS 238130). OSHA activity number 348237629.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Fast Lane Construction LLC. — free Get an email when a new federal OSHA severe-injury report for Fast Lane Construction LLC. is published. One employer, no account, unsubscribe in one click.
Site address
8573 CINCINNATI-DAYTON RD
City
WEST CHESTER
State
OH
ZIP
45069
Mailing
27 S GARLAND AVE, DAYTON, OH 45413
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
7
Ownership type
A

3 citations on file for this inspection.

1926.501 B01

Serious Gravity 10 1 instance 2 exposed
Issued
Jul 21, 2025
Abate by
Aug 25, 2025
Penalty
Initial $4,965 · Current $3,476 Reduced
29 CFR  1926.501(b)(1):"Unprotected sides and edges." Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.  a) On or about?May?8,?2025, the employer failed to ensure that employees were protected by a guardrail system, safety net, or personal fall?arrest system while installing trim along an unprotected flat?roof edge. As a result, employees were exposed to a 15?foot fall hazard to the level below.
Recent events (2)
  • — I (S) $3475.5
  • — Z (S) $4965

1926.502 D08

Serious Gravity 10 1 instance 2 exposed
Issued
Jul 21, 2025
Abate by
Aug 25, 2025
Penalty
Initial $4,965 · Current $3,476 Reduced
29 CFR  1926.502(d)(8): Horizontal lifelines shall be designed, installed, and used, under the supervision of a qualified person, as part of a complete personal fall arrest system, which maintains a safety factor of at least two.   a) On or about?May?8,?2025, the employer failed to ensure the horizontal lifeline used by employees installing metal trim was properly designed and anchored under a qualified person's supervision. As a result, employees were exposed to an uncontrolled fall of approximately?15?feet to the ground below.
Recent events (2)
  • — I (S) $3475.5
  • — Z (S) $4965

1926.502 D15

Other-than-serious 1 instance 1 exposed
Issued
Jul 21, 2025
Abate by
Aug 25, 2025
Penalty
Initial $0 · Current $0
29 CFR  1926.502(d)(15): Anchorages used for attachment of personal fall arrest equipment shall be independent of any anchorage being used to support or suspend platforms and capable of supporting at least 5,000 pounds (22.2 kN) per employee attached, or shall be designed, installed, and used as follows:    a) On?or?about?May?8,?2025, the employer failed to provide a 5,000?pound?rated anchorage for the horizontal lifeline; employees attached their fall?arrest gear to a kinked steel choker not designed for fall protection, exposing them to a 15?foot fall to the ground below.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348237629.