SOUTH PARIS, ME —
OSHA Inspection: PARICON, LLC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of PARICON, LLC. in 169 WESTERN AVENUE, SOUTH PARIS, ME 04281 (NAICS 493190). OSHA activity number 348244682.
Where did this inspection happen?
- Establishment
- PARICON, LLC.
- Site address
- 169 WESTERN AVENUE
- City
- SOUTH PARIS
- State
- ME
- ZIP
- 04281
- Mailing
- P.O. BOX 157, SOUTH PARIS, ME 04281
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 493190
- Employees
- 7
- Ownership type
- A
Citations
11 citations on file for this inspection.
1910.22 D01
- Issued
- Abate by
- Penalty
- Initial $4965.00 · Current $2483.00 Reduced
General-duty citation text
29 CFR 1910.22(d)(1): The employer did not ensure that walking-working surfaces are inspected, regularly and as necessary, and maintained in a safe condition: Loading Dock - Broken concrete along the edges of the metal dock plate were causing a tripping hazards.
Recent events (2)
- — I (S) $2482.5
- — Z (S) $4965
1910.37 A03
- Issued
- Abate by
- Penalty
- Initial $4256.00 · Current $2128.00 Reduced
General-duty citation text
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: The exit routes outside the building were obstructed with dense vegetation, in the following instances. a) 1st floor rear exit stairwell. b) Basement side door exit nearest the roadway.
Recent events (2)
- — I (S) $2128
- — Z (S) $4256
1910.157 E02
- Issued
- Penalty
- Initial $2128.00 · Current $1064.00 Reduced
General-duty citation text
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly: Establishment - The employer failed to ensure that fire extinguishers throughout the facility were inspected monthly.
Recent events (2)
- — I (S) $1064
- — Z (S) $2128
1910.178 A06
- Issued
- Abate by
- Penalty
- Initial $2128.00 · Current $1064.00 Reduced
General-duty citation text
29 CFR 1910.178(a)(6): The employer did not ensure that all nameplates and markings were in place: Warehouse - The Nissan powered industrial truck was missing its nameplate.
Recent events (2)
- — I (S) $1064
- — Z (S) $2128
1910.178 L01 I
- Issued
- Abate by
- Penalty
- Initial $4965.00 · Current $2483.00 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): Establishment - The employer did not conduct powered industrial truck training before allowing employees to operate trucks.
Recent events (2)
- — I (S) $2482.5
- — Z (S) $4965
1910.303 B07 I
- Issued
- Abate by
- Penalty
- Initial $3547.00 · Current $1774.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment: Basement - The electrical panel had unused openings due to missing several breakers, in the following instances. a) Location #13, (Loading dock receptacle) - Unused opening. b) Location #2, (Locations 4, 5, & 6) - No breakers installed and covered with black duct tape. c) Location #3, (Locations 7, 8, & 9) - No breakers installed, covered with black duct tape. d) Location #4, (Locations 22, 23, & 24) - No breakers installed, covered with black duct tape.
Recent events (2)
- — I (S) $1773.5
- — Z (S) $3547
1910.304 F01 VIII
- Issued
- Abate by
- Penalty
- Initial $3547.00 · Current $1774.00 Reduced
General-duty citation text
29 CFR 1910.304(f)(1)(viii): Circuit breakers used as switches in 120-volt and 277-volt, fluorescent lighting circuits were not listed and marked "SWD." Malden Mills Electrical Panel - The breaker being used to turn on/off the basement lights was not listed or marked for that type of use.
Recent events (2)
- — I (S) $1773.5
- — Z (S) $3547
1910.37 B02
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit": Basement, Rear - The exit door did not have a sign marked "Exit".
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.157 C01
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: Fire extinguishers were obstructed by product and debris, in the following instances. a) Basement - A fire extinguisher was obstructed by a pallet of sleds. b) Basement - A fire extinguisher was obstructed by a pallet filled with wood debris.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.157 G01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.157(g)(1): An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage firefighting: Establishment - The employer does not provide an educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage firefighting.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 G01
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: Basement - The main electrical panel was obstructed by a box of trash and construction debris.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 493190)
SAN ANTONIO, TX—2026-07-09
WAREHOUSE RACK COMPANY, LP
SANTA ANA, CA—2026-07-09
NGY GROUP (ORANGE COUNTY) INC.
CHICAGO, IL—2026-07-06
CHICAGO FURNITURE & MATTRESS WAREHOUSE DBA ULTIMATE FURNITURE & MATTRESS, INC.
GRESHAM, OR—2026-07-02
317744737 - VASCO SERVICES LLC
LINDON, UT—2026-06-29
SILHOUETTE AMERICA, INC.
More inspections in ME
PORTLAND, ME—2026-07-06
NEW ENGLAND REHABILITATION HOSPITAL OF PORTLAND
DOVER FOXCROFT, ME—2026-07-06
SHAW'S SUPERMARKETS
GORHAM, ME—2026-07-02
TOWN OF GORHAM
FARMINGTON, ME—2026-07-02
MCTA GENERAL CONSTRUCTION CORP
FARMINGTON, ME—2026-07-02
JC HOME IMPROVEMENT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348244682.