RANCOCAS, NJ —
OSHA Inspection: INDUCTOTHERM CORP.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of INDUCTOTHERM CORP. in 10 INDEL AVENUE P.O. BOX 157, RANCOCAS, NJ 08073 (NAICS 333249). OSHA activity number 348245234.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- INDUCTOTHERM CORP.
- Site address
- 10 INDEL AVENUE P.O. BOX 157
- City
- RANCOCAS
- State
- NJ
- ZIP
- 08073
- Mailing
- 10 INDEL AVENUE P.O. BOX 157, RANCOCAS, NJ 08073
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333249
- Employees
- 224
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.178 A04
- Issued
- Aug 11, 2025
- Abate by
- Sep 5, 2025
- Penalty
- Initial $8,512 · Current $8,512
General-duty citation text
29 CFR 1910.178(a)(4): Modifications and additions which affect capacity and safe operation of powered industrial truck were performed by the employer without the manufacturer's prior written approval: a) Inductotherm Corp. - Yard /Shipping Area: Employees were operating the Toyota Propane Forklift Model # 8FGC45U-BCS, S/N 20547, with the Forklift Aerial Platform attachment (36"x48") Model # H-2771 from Uline, used to lift employees, without obtaining the forklift manufacturer's written approval for the use of the attachment, occurred on or about 06/02/2025.
Recent events (2)
- — I (S) $8512
- — Z (S) $8512
1910.212 A01
- Issued
- Aug 11, 2025
- Abate by
- Sep 5, 2025
- Penalty
- Initial $14,188 · Current $14,188
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Inductotherm Corp. - Magnetic Components area: The Cincinnati Milling Machine Model #2, S/N 2A2PLR30 was not provided with a guard to cover the moving shaft attached to the back of the blade, observed on or about 05/14/2025.
Recent events (2)
- — I (S) $14188
- — Z (S) $14188
1910.212 A03 II
- Issued
- Aug 11, 2025
- Abate by
- Sep 5, 2025
- Penalty
- Initial $16,550 · Current $0 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a) Inductotherm Corp. - Magnetic Components area: The Cincinnati Milling Machine Model #2, S/N 2A2PLR30 was not provided with a guard to cover the blade, observed on or about 05/14/2025.
Recent events (2)
- — I (S) $0
- — Z (S) $16550
1904.41 A02
- Issued
- Aug 11, 2025
- Penalty
- Initial $2,837 · Current $1,500 Reduced
General-duty citation text
29 CFR 1904.41(a)(2): An establishment that had 20 or more employees but fewer than 250 employees at any time during the previous calendar year, and was classified in an industry listed in appendix A to subpart E of this part, did not electronically submit information from OSHA Form 300A Summary of Work-Related Injuries and Illnesses to OSHA or OSHA's designee. a) Inductotherm Corporation located at 10 Indel Avenue, Rancocas NJ 08073: On or about April 28, 2025, the employer failed to electronically submit information from their 2024 OSHA Form 300A or equivalent. The establishment employed 224 employees and was classified as NAICS 333994 during the calendar year 2024.
Recent events (2)
- — I (O) $1500
- — Z (O) $2837
1910.1200 F05
- Issued
- Aug 11, 2025
- Abate by
- Sep 5, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(5): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged, or marked with the identity and appropriate hazard warnings regarding the chemicals contained therein: a) Inductotherm Corp. - Cleaning Area next to Subsystems Department: Two tanks with Fuze Clean FS, a corrosive chemical, which was used to clean cooper, were not labeled with the appropriate hazard warnings for the chemical, observed on or about 05/14/2025.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Inductotherm Corp.
View Inductotherm Corp.'s full OSHA safety record →
More inspections in this industry (NAICS 333249)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348245234.