SUFFIELD, CT —
OSHA Inspection: HP HOOD LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of HP HOOD LLC in 1250 EAST STREET SOUTH, SUFFIELD, CT 06078 (NAICS 311520). OSHA activity number 348247719.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HP HOOD LLC
- Site address
- 1250 EAST STREET SOUTH
- City
- SUFFIELD
- State
- CT
- ZIP
- 06078
- Mailing
- 1250 EAST STREET SOUTH, SUFFIELD, CT 06078
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311520
- Employees
- 132
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.212 A03 III
- Issued
- Sep 15, 2025
- Abate by
- Oct 31, 2025
- Penalty
- Initial $10,640 · Current $0 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(iii): Special hand tools for placing and removing material(s) were not provided to permit easy handling of material without the operator placing a hand in the danger zone HP Hood LLC - freezer conveyor belt. On or about May 15, 2025 it was necessary for employees to reach over or through guards around the conveyor belt to un-jam product containers when they became stuck in a 90-degree transition between two belts.
Recent events (2)
- — I (S) $0
- — Z (S) $10640
1910.305 B02 I
- Issued
- Sep 15, 2025
- Penalty
- Initial $12,413 · Current $10,000 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: Production Area. On or about August 26, 2025 a three-phase, 408V electrical outlet adjacent to Work Center 6 was not equipped with a cover.
Recent events (2)
- — I (O) $10000
- — Z (S) $12413
More inspections at HP Hood LLC
View HP Hood LLC's full OSHA safety record →
More inspections in this industry (NAICS 311520)
More inspections in CT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348247719.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.