COCHRANTON, PA —
OSHA Inspection: BORTNICK CONSTRUCTION, INC.
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of BORTNICK CONSTRUCTION, INC. in 5123 VICTORY BLVD, COCHRANTON, PA 16314 (NAICS 238990). OSHA activity number 348247982.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BORTNICK CONSTRUCTION, INC.
- Site address
- 5123 VICTORY BLVD
- City
- COCHRANTON
- State
- PA
- ZIP
- 16314
- Mailing
- 146 BEAVER STREET PO BOX 30, SPRINGBORO, PA 16435
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238990
- Employees
- 25
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.132 A
- Issued
- Sep 29, 2025
- Abate by
- Oct 24, 2025
- Penalty
- Initial $3,618 · Current $3,700
General-duty citation text
1910.132(a) Protective equipment, including protective clothing, respiratory devices, and protective shields and barriers, shall be provided, used, and maintained wherever it is necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact. a.) Bortnick Construction, Inc., Bucket Elevator or line 2 emergency cullet elevator area located at a worksite at 5123 Victory Blvd. Cochranton, PA, on or about May 15th, 2025, and times prior thereto: The employer did not evaluate the workplace to determine if the bucket elevator was a permit required confined space prior to employees initiating work operations in the space. As an employee was maneuvering equipment in the bucket elevator, he was struck-by a falling object resulting in an injury. ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below). This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (O) $3700
- — Z (S) $3618
1910.146 D01
- Issued
- Sep 29, 2025
- Abate by
- Oct 24, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.146(d)(1): Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not implement the measures necessary to prevent unauthorized entry: a.) Bortnick Construction, Inc., Bucket Elevator or line 2 emergency cullet elevator area located at a worksite at 5123 Victory Blvd. Cochranton, PA, on or about May 15th, 2025, and times prior thereto: Measures were not taken to prevent unauthorized entry into a permit required confined space. Employees performed work tasks within the line 2 emergency cullet elevator with their hands, arms and head crossing the plane of the confined space. An employee was struck by a piece of metal in the space while performing the removal of buckets from the bucket elevator. ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below). This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.146 C07 III
- Issued
- Sep 29, 2025
- Abate by
- Oct 24, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.146(c)(7)(iii): The employer did not document the basis for determining that all hazards in a permit space had been eliminated, through a written certification that contained the date, the location of the space, and the signature of the person that made the determination: a.) Bortnick Construction, Inc., Bucket Elevator or line 2 emergency cullet elevator area located at a worksite at 5123 Victory Blvd. Cochranton, PA, on or about May 15th, 2025, and times prior thereto: The employer did not document the basis for determination that all hazards in the bucket elevator had been eliminated before performing work operations in the permit required confined space. As an employee was maneuvering equipment in the bucket elevator, he was struck-by a falling object resulting in an injury. ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below). This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.146 G01
- Issued
- Sep 29, 2025
- Abate by
- Oct 24, 2025
- Penalty
- Initial $3,618 · Current $0 Reduced
General-duty citation text
29 CFR 1910.146(g)(1): The employer did not provide training so that all employees whose work was regulated by 29 CFR 1910.146 (permit required confined spaces) acquired the understanding, knowledge, and skills necessary for the safe performance of the duties assigned under 29 CFR 1910.146: a.) Bortnick Construction, Inc., Bucket Elevator or line 2 emergency cullet elevator area located at a worksite at 5123 Victory Blvd. Cochranton, PA, on or about May 15th, 2025, and times prior thereto: Employees had not received complete and effective permit required confined space training in that a work area at the job site was not properly identified as a permit required confined space prior to employees initiating work operations. ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below). This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $3618
More inspections in this industry (NAICS 238990)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348247982.