Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: REYES MASONRY LLC

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of REYES MASONRY LLC in 607 WHITE HILLS DRIVE, ROCKWALL, TX 75032 (NAICS 238140). OSHA activity number 348248543.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Reyes Masonry LLC — free Get an email when a new federal OSHA severe-injury report for Reyes Masonry LLC is published. One employer, no account, unsubscribe in one click.
Establishment
REYES MASONRY LLC
Site address
607 WHITE HILLS DRIVE
City
ROCKWALL
State
TX
ZIP
75032
Mailing
1731 BELMONT ST, MESQUITE, TX 75149
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238140
Employees
7
Ownership type
A

6 citations on file for this inspection.

1926.451 B01 I

Serious Gravity 10 1 instance 2 exposed
Issued
Nov 10, 2025
Abate by
Dec 8, 2025
Penalty
Initial $4,965 · Current $4,965
29 CFR  1926.451(b)(1)(i): Each platform unit was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide.   (a)	On or about May 14, 2025, at the back wall of an two-story commercial new build car wash building, where employee was installing rebar from the second-tiered scaffold that was not fully planked.
Recent events (1)
  • — Z (S) $4965

1926.451 E01

Serious Gravity 10 1 instance 2 exposed
Issued
Nov 10, 2025
Abate by
Dec 8, 2025
Penalty
Initial $4,965 · Current $4,965
29 CFR  1926.451(e)(1):When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used.  Cross braces were used as a means of access.  (a)	On or about May 14, 2025, employees doing  masonry work on a commercial new build car wash while working from a two-tier scaffold system where a ladder was not available for safe access.
Recent events (1)
  • — Z (S) $4965

1926.451 F06

Serious Gravity 10 1 instance 2 exposed
Issued
Nov 10, 2025
Abate by
Dec 8, 2025
Penalty
Initial $4,965 · Current $4,965
29 CFR  1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6).  On or about May 14, 2025, employees doing masonry work on a commercial new build car wash while working  and a piece of rebar came in contact to overhead power line.
Recent events (1)
  • — Z (S) $4965

1926.451 F07

Serious Gravity 1 1 instance 7 exposed
Issued
Nov 10, 2025
Abate by
Dec 8, 2025
Penalty
Initial $2,128 · Current $2,128
29 CFR  1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:  (a) On or about May 14, 2025, at the back wall of front entry of an two-story commercial building, employees erecting a tubular welded frame scaffold were not trained under the supervision and direction of a competent person.
Recent events (1)
  • — Z (S) $2128

1926.454 B

Serious Gravity 1 1 instance 7 exposed
Issued
Nov 10, 2025
Abate by
Dec 8, 2025
Penalty
Initial $0 · Current $0
29 CFR  1926.454(b): The employer did not have each employee involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the work in question.  (a)	On or about May 14, 2025, at the back wall of front entry of an two-story commercial building, employees utilized a scaffold without being trained by a competent person while using the scaffold on the interior wall of the building.
Recent events (1)
  • — Z (S) $0

1926.451 G01 VII

Serious Gravity 10 1 instance 2 exposed
Issued
Nov 10, 2025
Abate by
Dec 8, 2025
Penalty
Initial $4,965 · Current $4,965
29 CFR  1926.451(g)(1)(vii):For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.  (a)	On or about May 14, 2025, at the back wall of an two-story commercial new build car wash building, where employee was installing rebar from the second-tiered scaffold that was not protected from falls.
Recent events (1)
  • — Z (S) $4965

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348248543.