Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GREE MECHANICAL YONKERS LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of GREE MECHANICAL YONKERS LLC in 1876 CENTRAL PARK AVENUE, YONKERS, NY 10710 (NAICS 238220). OSHA activity number 348253535.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Gree Mechanical Yonkers LLC — free Get an email when a new federal OSHA severe-injury report for Gree Mechanical Yonkers LLC is published. One employer, no account, unsubscribe in one click.
Site address
1876 CENTRAL PARK AVENUE
City
YONKERS
State
NY
ZIP
10710
Mailing
1900 CENTRAL PARK AVENUE, YONKERS, NY 10710
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
13
Ownership type
A

4 citations on file for this inspection.

1926.451 B01

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Oct 21, 2025
Penalty
Initial $4,965 · Current $0 Reduced
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports   Location: 1900 Central Park Avenue, Yonkers, NY  a) On or about May 15, 2025, employees were exposed to fall hazards of approximately 12 feet while working on the south side of the building from a fabricated frame scaffold that was not fully planked.
Recent events (3)
  • — F (S) $0
  • — C (S) $4965
  • — Z (S) $4965

1926.451 E01

Deleted Serious Gravity 5 1 instance 4 exposed
Issued
Oct 21, 2025
Penalty
Initial $3,547 · Current $0 Reduced
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used.  Cross braces were used as a means of access.  Location: 1900 Central Park Avenue, Yonkers, NY  a) On or about June 4, 2025, employees working from a fabricated from scaffold on the north side of the building used cross braces and end frames as a means to access upper working levels exposing them to fall hazards up to approximately 12 feet.
Recent events (3)
  • — F (S) $0
  • — C (S) $3547
  • — Z (S) $3547

1926.451 G04 II

Deleted Serious Gravity 10 2 instances 3 exposed
Issued
Oct 21, 2025
Penalty
Initial $4,965 · Current $0 Reduced
29 CFR 1926.451(g)(4)(ii): The top edge height of toprails on scaffolds manufactured or placed in service after January 1, 2000 were not installed between 38 and 45 inches above the platform surface and installed between 36 and 45 inches above the platform surface on scaffolds manufactured or placed in service before January 1, 2000.  Location: 1900 Central Park Avenue, Yonkers, NY  a) On or about May 15, 2025, employees working on the south side of the building from a fabricated fame scaffold without a toprail were exposed to fall hazards of approximately 12 feet.  b) On or about June 4, 2025, employees working on the north side of the building from a fabricated frame scaffold without a toprail were exposed to fall hazards of approximately 12 feet.
Recent events (3)
  • — F (S) $0
  • — C (S) $4965
  • — Z (S) $4965

1926.501 B10

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Oct 21, 2025
Penalty
Initial $4,965 · Current $0 Reduced
29 CFR  1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system.   Location: 1900 Central Park Avenue, Yonkers, NY  a) On or about May 15, 2025, two employees were engaged building an approximately 1 foot parapet on a low slope roof and were not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Employees were exposed to falls of approximately 15' to the pavement below.
Recent events (3)
  • — F (S) $0
  • — C (S) $4965
  • — Z (S) $4965

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348253535.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.