Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: BECTON, DICKINSON AND COMPANY

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of BECTON, DICKINSON AND COMPANY in 1852 10TH AVENUE, COLUMBUS, NE 68601 (NAICS 339112). OSHA activity number 348257197.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Becton, Dickinson and Company for free Get an email when a new federal OSHA severe-injury report for Becton, Dickinson and Company is published. One employer, no account, unsubscribe in one click.
Site address
1852 10TH AVENUE
City
COLUMBUS
State
NE
ZIP
68601
Mailing
1852 10TH AVENUE, COLUMBUS, NE 68601
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
339112
Employees
1244
Ownership type
Private (A)

7 citations on file for this inspection.

1910.147 D04 I

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 26, 2025
Abate by
Jan 15, 2026
Penalty
Initial $12,059 · Current $8,441 Reduced
29 CFR  1910.147(d)(4)(i):Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:  On or about May 20th, 2025, employees engaged in cleaning and maintenance related activities located at 1852 10th Ave, Columbus, Nebraska 68601, were exposed to electrical and pneumatic energy sources in that the operators and the set-up operators for the 850 #1 machine were not applying locks to machine 850 #1 prior to performing work inside machine.
Recent events (2)
  • · I (S) $8441.3
  • · Z (S) $12059

1910.147 C07 I A

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 26, 2025
Abate by
Jan 15, 2026
Penalty
Initial $0 · Current $0
29 CFR  1910.147(c)(7)(i)(A):Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation.   On or about May 15th, 2025, employees engaged in cleaning and maintenance related activities at 1852 10th Ave, Columbus, Nebraska 68601, were exposed to electrical and pneumatic energy sources  when accessing machine 850 #1 in that the employer was allowing authorized LOTO operators access and perform work inside the 850#1 without receiving authorized LOTO training.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.305 A02 X

Serious Gravity 1 1 instance 1 exposed
Issued
Sep 26, 2025
Penalty
Initial $6,150 · Current $4,305 Reduced
29 CFR  1910.305(a)(2)(x):Flexible cords and cables were not protected from accidental damage.  On or about May 20th, 2025, employees engaged in manufacturing operations located at 1852 10th Ave, Columbus, Nebraska 68601, were exposed to fire and electrical hazards in that a damaged flexible cord was plugged into the VIBRO BLOCK FEEDER.  The flexible cord outer sheathing was damaged and was exposing energized 120V.
Recent events (2)
  • · I (S) $4305
  • · Z (S) $6150

1910.334 A02 I

Serious Gravity 1 1 instance 1 exposed
Issued
Sep 26, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.334(a)(2)(i):Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket):  On or about May 20th, 2025, employees engaged in manufacturing operations located at 1852 10th Ave, Columbus, Nebraska 68601, were exposed to electrical and fire hazards in that the employer was not inspecting flexible cords.  The employer was using a damaged flexible cord that was plugged into the VIBRO BLOCK FEEDER.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.305 B01 II

Serious Gravity 1 1 instance 1 exposed
Issued
Sep 26, 2025
Penalty
Initial $6,150 · Current $4,305 Reduced
29 CFR  1910.305(b)(1)(ii):Unused openings in boxes, cabinets, or fittings were not effectively closed:  On or about May 20th, 2025, employees engaged in manufacturing operations located at 1852 10th Ave, Columbus, Nebraska 68601, were exposed to fire and electrical hazards in that the cabinet door located on the VIBRO BLOCK Controller had an opening located on the bottom right hand corner and was not protecting employees from incidental contact with energized conductors.
Recent events (2)
  • · I (S) $4305
  • · Z (S) $6150

1910.305 B01 III D

Serious Gravity 1 1 instance 2 exposed
Issued
Sep 26, 2025
Penalty
Initial $6,150 · Current $4,305 Reduced
29 CFR  1910.305(b)(1)(iii)(D):The raceway is sealed or plugged at the outer end using approved means so as to prevent access to the enclosure through the raceway.   On or about May 20th, 2025, employees engaged in manufacturing operations located at 1852 10th Ave, Columbus, Nebraska 68601, were exposed to fire and electrical hazards in that the conduit that was ran to the oven blowers on the back of the curing oven  was not sealed or plugged at the outer end.  The Conduit was hanging freely and was exposing energized 120V conductors.
Recent events (2)
  • · I (S) $4305
  • · Z (S) $6150

1910.305 G02 III

Serious Gravity 5 1 instance 2 exposed
Issued
Sep 26, 2025
Penalty
Initial $10,251 · Current $7,176 Reduced
29 CFR  1910.305(g)(2)(iii):Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:  On or about May 20th, 2025, employees engaged in manufacturing operations located at 1852 10th Avenue, Columbus, Nebraska 68601, were exposed to fire and electrical hazards in that electrical cabinet that supplies power to the conveyor motor on machine 850 #1 did not contain a device or fitting that would prevent the energized cable from damage.  The cable inserted into the cabinet had damage to the outer sheathing and was exposing energized 230V.
Recent events (2)
  • · I (S) $7175.7
  • · Z (S) $10251

View Becton, Dickinson and Company's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 348257197.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.