Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WELL WERKS ENERGY, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of WELL WERKS ENERGY, LLC in NORTH OF 63RD ST NW 48�19'45.6"N 103�21'25.7"W, EPPING, ND 58843 (NAICS 213112). OSHA activity number 348262346.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Well Werks Energy, LLC — free Get an email when a new federal OSHA severe-injury report for Well Werks Energy, LLC is published. One employer, no account, unsubscribe in one click.
Site address
NORTH OF 63RD ST NW 48�19'45.6"N 103�21'25.7"W
City
EPPING
State
ND
ZIP
58843
Mailing
71677 RIVERSIDE DRIVE, COVINGTON, LA 70433
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213112
Employees
301
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 2 exposed
Issued
Nov 13, 2025
Penalty
Initial $13,240 · Current $9,268 Reduced
Section (5)(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees who were exposed to fire and explosion hazards:    (a) On May 17, 2025, at well site Carpenter 5, near Epping, North Dakota, the employer failed to ensure employees were protected from fire and explosion hazards while performing flow back operations where a flash fire occurred when crude oil and natural gas were discharged at 160 psi into a metal bucket without bonding or grounding the bucket to the manifold to prevent static discharge.    Abatement Note: Among other methods, feasible and acceptable abatement methods to correct this hazard is to follow API RP 54 - Occupational Safety and Health for Oil and Gas Well Drilling and Servicing Operations, Section 16 - Flowback Operations. Section 16.11 states "All equipment shall be bonded and grounded when in use."
Recent events (2)
  • — I (S) $9268
  • — Z (S) $13240

View Well Werks Energy, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348262346.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.