Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: JUAN CASTANEDA DBA JUAN CASTANEDA DBA CASTANEDA RENOVATIONS

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of JUAN CASTANEDA DBA JUAN CASTANEDA DBA CASTANEDA RENOVATIONS in 956 S. CEDAR AVE., ELMHURST, IL 60126 (NAICS 238160). OSHA activity number 348265166.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Juan Castaneda DBA Juan Castaneda DBA Castaneda Renovations — free Get an email when a new federal OSHA severe-injury report for Juan Castaneda DBA Juan Castaneda DBA Castaneda Renovations is published. One employer, no account, unsubscribe in one click.
Site address
956 S. CEDAR AVE.
City
ELMHURST
State
IL
ZIP
60126
Mailing
5913 S GREEN ST, CHICAGO, IL 60621
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

3 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 5 exposed
Issued
Jul 16, 2025
Abate by
Aug 6, 2025
Penalty
Initial $4,965 · Current $4,965
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system:  On or about May 16, 2025 , Employees were exposed to fall hazards of approximately 18 feet while engaged in residential construction activities. Fall protection was not being utilized while employees were engaged in roofing activities.  Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (1)
  • — Z (S) $4965

1926.503 B01

Serious Gravity 1 1 instance 5 exposed
Issued
Jul 16, 2025
Abate by
Aug 4, 2025
Penalty
Initial $2,128 · Current $2,128
29 CFR 1926.503(b)(1): The employer shall verify compliance with paragraph (a) of this section by preparing a written certification record. The written certification record shall contain the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. If the employer relies on training conducted by another employer or completed prior to the effective date of this section, the certification record shall indicate the date the employer determined the prior training was adequate rather than the date of actual training.    On or about May 16, 2025, the employer did not certify that employees had been trained to recognize and minimize fall hazards. Employees were exposed to fall hazards of approximately 18 feet while performing roofing activities without using fall protection.   Abatement documentation is required for this item in accordance with 29 CFR 1903.19(c).
Recent events (1)
  • — Z (S) $2128

1926.1053 B01

Serious Gravity 1 1 instance 1 exposed
Issued
Jul 16, 2025
Abate by
Aug 4, 2025
Penalty
Initial $2,128 · Current $2,128
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grab rail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.   On or about May 16, 2025, the portable ladder used to access the roof level did not extend at least three (3') feet above the upper landing surface, thereby exposing employees to fall hazards.  Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).