STATE COLLEGE, PA —
OSHA Inspection: MID-STATE ROOFING AND COATING, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of MID-STATE ROOFING AND COATING, INC. in THOMPSON BUILDING PENN STATE UNIVERSITY, STATE COLLEGE, PA 16801 (NAICS 238160). OSHA activity number 348270489.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MID-STATE ROOFING AND COATING, INC.
- Site address
- THOMPSON BUILDING PENN STATE UNIVERSITY
- City
- STATE COLLEGE
- State
- PA
- ZIP
- 16801
- Mailing
- 375 NEW HOLLAND DRIVE, BELLEVILLE, PA 17004
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 13
- Ownership type
- A
Citations
1 citation on file for this inspection.
1926.454 C03
- Issued
- Sep 9, 2025
- Abate by
- Sep 26, 2025
- Penalty
- Initial $14,895 · Current $11,000 Reduced
General-duty citation text
1926.454(c)(3) The employer failed to retrain employees that showed indications through work performance of not retaining the requisite proficiency: Thompson Building, Penn State University - On or about May 27, 2025, a mid-rail on the scaffold in use did not withstand the required applied force and exposed a worker to a fall in excess of 30 feet to grade. Employees lacked the skill or understanding needed for the safe erection of the scaffolding in that they did not understand the applied forces to the guardrail system and /or the proper techniques to install the guardrail system. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (O) $11000
- — Z (S) $14895
More inspections at Mid-State Roofing and Coating, INC.
View Mid-State Roofing and Coating, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348270489.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.