SAN ANTONIO, TX —
OSHA Inspection: GOOD ELECTRIC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of GOOD ELECTRIC in 601 RAYMOND MEDINA ST. SUITE 5, SAN ANTONIO, TX 78226 (NAICS 238210). OSHA activity number 348271966.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GOOD ELECTRIC
- Site address
- 601 RAYMOND MEDINA ST. SUITE 5
- City
- SAN ANTONIO
- State
- TX
- ZIP
- 78226
- Mailing
- 9018 AERO STREET, SAN ANTONIO, TX 78217
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- Employees
- 10
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C01
- Issued
- Sep 24, 2025
- Abate by
- Oct 21, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(1):The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: On or about May 23, 2025, at the main distribution panel, a Lockout Tagout (LOTO) program and procedures were not implemented.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.303 G02 I B
- Issued
- Sep 24, 2025
- Abate by
- Oct 21, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(2)(i)(B):Except as elsewhere required or permitted by this standard, live parts of electrical equipment operating at 50 volts or more was not guarded by suitable permanent, substantial partitions or screens so arranged so that only qualified persons would have access to the space within reach of the live parts. Any openings in such partitions or screens were not so sized and located that persons were not likely to come into accidental contact with the live parts or to bring conducting objects into contact with them: On or about May 23, 2025, at the main distribution panel, while working near live parts, an electrical distribution panel was not securely covered.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.335 A01 I
- Issued
- Sep 24, 2025
- Abate by
- Oct 21, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.335(a)(1)(i):Employees working in areas where there were potential electrical hazards were not using electrical protective equipment that was appropriate for the specific parts of the body to be protected and for the work to be performed: On or about May 23, 2025, on the main distribution panel, an employee assisted in running a metal fishing line near a live electrical panel without any PPE.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.335 A02 I B
- Issued
- Sep 24, 2025
- Abate by
- Oct 21, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.335(a)(2)(i)(B):Ropes and hand lines used near exposed energized parts were not nonconductive: On or about May 23, 2025, on the main distribution panel, employees were running a metal fishing line through a conduit with an exposed live main distribution panel.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 238210)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348271966.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.