BOSTON, MA ·
OSHA Inspection: REVOLUTIONARY SPACES, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of REVOLUTIONARY SPACES, INC. in 310 WASHINGTON STREET AND 1 STATE STREET, BOSTON, MA 02109 (NAICS 712120). OSHA activity number 348273376.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- REVOLUTIONARY SPACES, INC.
- Site address
- 310 WASHINGTON STREET AND 1 STATE STREET
- City
- BOSTON
- State
- MA
- ZIP
- 02109
- Mailing
- 310 WASHINGTON STREET, BOSTON, MA 02109
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 712120
- Employees
- 18
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1910.36 G02
- Issued
- Jun 26, 2025
- Abate by
- Aug 15, 2025
- Penalty
- Initial $4,220 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.36(g)(2):Exit access(es) were not at least 28 inches (71.1 cm) wide at all points. Office and Product Storage Space: a. A hallway leading out of breakroom and back offices, measured 25 inches wide due to boxes stored along the wall, exposing employee to a limited egress path in the event of an emergency. b. A second Exit door along egress path out of the building only opened 24 inches, due to installed equipment in the space, exposing employees to a limited egress path in the event of an emergency. Yarn Shop: c. Egress paths out of the storage space measures 24 inch, and 17 inches due to stock of boxes limiting width of paths, exposing employees to a limited egress path in event of an emergency.
Recent events (2)
- · I (S) $1500
- · Z (S) $4220
1910.37 B02
- Issued
- Jun 26, 2025
- Abate by
- Aug 15, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(2):Each exit was not clearly visible and marked by a sign reading "Exit": a. Office and Product Storage Space: The door leading out of the workspace was not marked with an EXIT sign. b. Yarn Shop: Door leading out of the workspace were not marked with an EXIT sign
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.157 E03
- Issued
- Jun 26, 2025
- Abate by
- Aug 15, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(3):Portable fire extinguishers were not subjected to an annual maintenance check: Office and Product Storage Space: There were two mounted portable fire extinguishers, available for use, with annual inspection dates of 2014 and 2015.