Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: STANCHEM INCORPORATED

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of STANCHEM INCORPORATED in 401 BERLIN STREET, EAST BERLIN, CT 06023 (NAICS 325510). OSHA activity number 348278060.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Stanchem Incorporated — free Get an email when a new federal OSHA severe-injury report for Stanchem Incorporated is published. One employer, no account, unsubscribe in one click.
Site address
401 BERLIN STREET
City
EAST BERLIN
State
CT
ZIP
06023
Mailing
401 BERLIN STREET, EAST BERLIN, CT 06023
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325510
Employees
48
Ownership type
A

3 citations on file for this inspection.

1910.132 A

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 29, 2025
Abate by
Oct 17, 2025
Penalty
Initial $6,207 · Current $4,345 Reduced
29 CFR  1910.132(a):Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered:  Building 27:  On, or about, June 13, 2025, employees who performed maintenance activities on or around tanks, vessels and piping that contained or had contained flammable liquids were not provided with flame-resistant clothing.
Recent events (2)
  • — I (S) $4344.9
  • — Z (S) $6207

1910.132 D01

Serious Gravity 5 1 instance 10 exposed
Issued
Aug 29, 2025
Abate by
Oct 17, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.132(d)(1):  The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE):  Facility:  On, or about, June 13, 2025, the employer had not conducted a Hazard Assessment to determine what personal protective equipment was needed for various tasks in the plant including, but not limited to, production and maintenance operations.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.335 A01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 29, 2025
Abate by
Oct 17, 2025
Penalty
Initial $4,965 · Current $3,476 Reduced
29 CFR  1910.335(a)(1)(i):  Employees working in areas where there were potential electrical hazards were not provided and/or were not using with electrical protective equipment that was appropriate for the specific parts of the body that needed to be protected and for the work being performed:  Facility:  On, or about, June 13, 2025, personal protective equipment such as, but not limited to, voltage rated gloves, fire resistive clothing, face shields, balaclavas, hard hats and hearing protection were not provided to and/or worn by employees who performed live electrical work, including trouble-shooting, or who verified that electrical equipment was properly de-energized.  At the time of the inspection, personal protective equipment that was more suitable to be worn while working on or around equipment at lower voltages, such as 120 volts, was not provided.
Recent events (2)
  • — I (S) $3475.5
  • — Z (S) $4965