LUBBOCK, TX —
OSHA Inspection: HT ENERGY LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of HT ENERGY LLC in 602 E COUNTY RD 7200, LUBBOCK, TX 79401 (NAICS 213112). OSHA activity number 348283227.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HT ENERGY LLC
- Site address
- 602 E COUNTY RD 7200
- City
- LUBBOCK
- State
- TX
- ZIP
- 79401
- Mailing
- 1415 BUDDY HOLLY AVE, LUBBOCK, TX 79401
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213112
- Employees
- 4
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.133 A01
- Issued
- Jul 31, 2025
- Abate by
- Aug 28, 2025
- Penalty
- Initial $6,620 · Current $3,972 Reduced
General-duty citation text
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation On or about May 23, 2025, at the mechanical shop, employees utilized a torch without the adequate eye/face protection while fixing a ladder on a derrick.
Recent events (2)
- — I (S) $3972
- — Z (S) $6620
1910.253 B02 IV
- Issued
- Jul 31, 2025
- Abate by
- Aug 28, 2025
- Penalty
- Initial $4,965 · Current $2,979 Reduced
General-duty citation text
29 CFR 1910.253(b)(2)(iv):Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use On or about May 23, 2025, at the mechanical shop, employees placed welding set (oxygen/acetylene) in storage, without taking the valves off when not in use.
Recent events (2)
- — I (S) $2979
- — Z (S) $4965
1910.253 B04 III
- Issued
- Jul 31, 2025
- Abate by
- Aug 28, 2025
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating On or about May 23, 2025, at the mechanical shop, employees stored a welding set (oxygen/acetylene) together without a separation between the cylinders.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at HT Energy LLC
View HT Energy LLC's full OSHA safety record →
More inspections in this industry (NAICS 213112)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348283227.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.