OSHA Inspection: MINGO AEROSPACE LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of MINGO AEROSPACE LLC in 11310 E. 81ST ST. N., OWASSO, OK 74055 (NAICS 336413). OSHA activity number 348305517.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mingo Aerospace LLC — free Get an email when a new federal OSHA severe-injury report for Mingo Aerospace LLC is published. One employer, no account, unsubscribe in one click.
Establishment
MINGO AEROSPACE LLC
Site address
11310 E. 81ST ST. N.
City
OWASSO
State
OK
ZIP
74055
Mailing
11310 E. 81ST ST. N., OWASSO, OK 74055
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
336413
Employees
119
Ownership type
A

5 citations on file for this inspection.

1910.1000 A02

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Dec 11, 2025
Abate by
Jan 8, 2026
Penalty
Initial $14,895 · Current $0 Reduced

Hazardous substances 0720

29 CFR 1910.1000(a)(2): Employee(s) were exposed to an airborne concentration of Cobalt listed in Table Z-1 in excess of the 8 hour Time Weighted Average concentration of 0.1 mg/m3:  On June 18, 2025, located in the thermal spray area at booth 1, an employee was exposed to Cobalt in excess of 0.1 milligrams per cubic meter of air during thermal spray operations.
Recent events (3)
  • — F (S) $0
  • — C (S) $14895
  • — Z (S) $14895

1910.1026 C

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Dec 11, 2025
Abate by
Jan 8, 2026
Penalty
Initial $14,895 · Current $0 Reduced

Hazardous substances 0689

29 CFR 1910.1026(c): Employees were exposed to an airborne concentration of chromium (VI) which exceeded 5 micrograms per cubic meter of air, as an 8-hour time-weighted average:  On September 12, 2025, located in the paint booth area, an employee was exposed to chromium (VI) in excess of 5 micrograms per cubic meter of air during paint spraying operations.
Recent events (3)
  • — F (S) $0
  • — C (S) $14895
  • — Z (S) $14895

1910.1026 D02 I

Deleted Serious Gravity 10 2 instances 10 exposed
Issued
Dec 11, 2025
Abate by
Jan 8, 2026
Penalty
Initial $14,895 · Current $0 Reduced

Hazardous substances 0689

29 CFR 1910.1026(d)(2)(i): The employer using the scheduled monitoring option did not perform initial monitoring to determine the 8-hour time-weighted average exposure to chromium (VI) for each employee on the basis of a sufficient number of personal breathing zone air samples to accurately characterize full shift exposure on each shift, for each job classification, in each work area:  a.) On or about June 11, 2025, and at times prior, located in the thermal spray department, initial personal breathing zone air monitoring for chromium (VI) was not conducted for employees who thermal sprayed airline parts using high velocity oxygen fuel (HVOF) that may produce chromium (VI).   b.) On or about June 11, 2025, and at times prior, located in the grind shop, initial personal breathing zone air monitoring for chromium (VI) was not conducted for employees who grind on airline parts containing chromium (VI).
Recent events (3)
  • — F (S) $0
  • — C (S) $14895
  • — Z (S) $14895

1910.1026 H03 II

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Dec 11, 2025
Abate by
Jan 8, 2026
Penalty
Initial $10,641 · Current $0 Reduced

Hazardous substances 0689

29 CFR 1910.1026(h)(3)(ii): The employer did not prohibit the removal of chromium (VI) from protective clothing and equipment by blowing, shaking, or any other means that dispersed chromium (VI) into the air or onto an employee's body:  On or about June 11, 2025, and at times prior, located in the paint booth, the employer did not prohibit employees from using compressed air to clean chromium (VI) containing dust from their protective clothing.
Recent events (3)
  • — F (S) $0
  • — C (S) $10641
  • — Z (S) $10641

1910.1026 I01

Other-than-serious Gravity 10 1 instance 1 exposed
Issued
Dec 11, 2025
Abate by
Jan 8, 2026
Penalty
Initial $14,895 · Current $8,937 Reduced

Hazardous substances 0689

29 CFR 1910.1026(i)(1): The employer did not provide change rooms, in conformance with the Sanitation standard, 29 CFR 1910.141, for employees who were required to change their clothes to use protective clothing and equipment for chromium (VI) exposures:  On or about June 11, 2025, and at times prior, located in the paint department, the employer did not provide a separate change room for employee's chromium (VI) contaminated protective clothing and their street clothing.
Recent events (3)
  • — F (O) $8937
  • — C (S) $14895
  • — Z (S) $14895

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348305517.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.