OSHA Inspection: CHRIS CONSTRUCTION AND GARAGE DESIGN, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CHRIS CONSTRUCTION AND GARAGE DESIGN, INC. in 117 S RIDGELAND, OAK PARK, IL 60302 (NAICS 238130). OSHA activity number 348309733.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Chris Construction AND Garage Design, INC. — free Get an email when a new federal OSHA severe-injury report for Chris Construction AND Garage Design, INC. is published. One employer, no account, unsubscribe in one click.
Site address
117 S RIDGELAND
City
OAK PARK
State
IL
ZIP
60302
Mailing
183 BLUEBURT CT, HAWTHORN WOODS, IL 60047
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238130
Employees
4
Ownership type
A

4 citations on file for this inspection.

1926.102 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 30, 2025
Abate by
Oct 27, 2025
Penalty
Initial $2,270 · Current $1,400 Reduced
29 CFR 1926.102(a)(1): Employees were not provided with eye and face protection equipment when machines or operations present potential eye or face injury from physical, chemical, or radiation agents:   a) On June 5, 2025, employees were exposed to eye injury while operating a pneumatic nail gun without eye protection during roofing work.   In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2270

1926.416 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 30, 2025
Abate by
Oct 27, 2025
Penalty
Initial $2,838 · Current $1,500 Reduced
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used:  a) On June 5, 2025, extension cord used by employees to power handheld circular saw had been damaged and lacked insulation.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2838

1926.501 B13

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 30, 2025
Abate by
Oct 27, 2025
Penalty
Initial $3,972 · Current $2,100 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):  a) On June 5, 2025, employees performing roofing work were exposed to fall hazards of approximately 12.8 feet.  In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3972

1926.1053 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 30, 2025
Abate by
Oct 27, 2025
Penalty
Initial $2,838 · Current $1,500 Reduced
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access:   a) On June 5, 2025, employees were using an extension ladder which did not extend 3 feet above the upper landing being accessed.   In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2838

View Chris Construction AND Garage Design, INC.'s full OSHA safety record →