Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CARLOS CRUZ VARGAS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CARLOS CRUZ VARGAS in 7201-7299 MAPLE BROOK LANE LOT 44, HOSCHTON, GA 30548 (NAICS 238170). OSHA activity number 348314873.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Carlos Cruz Vargas — free Get an email when a new federal OSHA severe-injury report for Carlos Cruz Vargas is published. One employer, no account, unsubscribe in one click.
Establishment
CARLOS CRUZ VARGAS
Site address
7201-7299 MAPLE BROOK LANE LOT 44
City
HOSCHTON
State
GA
ZIP
30548
Mailing
806 FARM CREEK ROAD NE, WOODSTOCK, GA 30188
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238170
Employees
2
Ownership type
A

4 citations on file for this inspection.

1926.102 A01

Serious Gravity 1 1 instance 2 exposed
Issued
Aug 8, 2025
Penalty
Initial $2,128 · Current $2,128
29 CFR 1926.102(a)(1): The employer did not ensure employees used eye and face protection equipment when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents:  a) New residential construction located on  Lot 44  Maplebrook Lane, Hoschton, GA, 30548, Scaffold: On or about 06/16/2026, the employer exposed employees to struck-by hazards while operating pneumatic nail guns, in that eye protection was not provided as employees engaged in siding activities were operating these tools at 95 PSI.
Recent events (1)
  • — Z (S) $2128

1926.451 G01 VII

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 8, 2025
Penalty
Initial $2,837 · Current $2,837
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.    a) New residential construction located on Lot 44 Maplebrook Lane, Hoschton, GA, 30548, Scaffold: On or about 06/16/2026, the employer exposed employees to fall hazards of 20-feet, 3-inches to the lower level, in that a fall protection system was not provided to employees engaged in siding activities.
Recent events (1)
  • — Z (S) $2837

1926.1053 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 8, 2025
Penalty
Initial $2,837 · Current $2,837
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:   a) New residential construction located on Lot 44 Maplebrook Lane, Hoschton, GA, 30548, Front side of structure: On or about 06/16/2026; the employer exposed employees to fall hazards of 20-feet to the lower level, in that the ladder used was not extended at least 3-feet to allow for safe access and egress from the walking/working surface.
Recent events (1)
  • — Z (S) $2837

1926.1053 B16

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 8, 2025
Penalty
Initial $0 · Current $0
29 CFR  1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired.   a) New residential construction located on Lot 44 Maplebrook Lane, Hoschton, GA 30548, Front side of structure: On or about June 16, 2026, the employer did not remove from service a Werner 20-foot extension ladder that was missing the right foot. Employees used the defective ladder, exposing them to fall hazards up to 20 feet to the lower level.
Recent events (1)
  • — Z (S) $0

View Carlos Cruz Vargas's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348314873.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.