Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FUN CITY LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of FUN CITY LLC in 4600 JONESTOWN ROAD, HARRISBURG, PA 17109 (NAICS 238990). OSHA activity number 348327321.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch FUN City LLC — free Get an email when a new federal OSHA severe-injury report for FUN City LLC is published. One employer, no account, unsubscribe in one click.
Establishment
FUN CITY LLC
Site address
4600 JONESTOWN ROAD
City
HARRISBURG
State
PA
ZIP
17109
Mailing
4600 JONESTOWN ROAD, HARRISBURG, PA 17109
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238990
Employees
7
Ownership type
A

7 citations on file for this inspection.

1926.404 B01 I

Serious Gravity 1 1 instance 7 exposed
Issued
Dec 15, 2025
Abate by
Jan 20, 2026
Penalty
Initial $6,384 · Current $6,384
29 CFR 1926.404(b)(1)(i):  Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites.  A.) 4600 Jonestown Road, Harrisburg, PA, former Bon-Ton / new Fun City section of the Colonial Park Mall - Employees were utilizing a flexible electrical extension cord to power a relocatable power tap which provided power to electrical equipment including, but not limited to, battery chargers.  The flexible electrical extension cord, relocatable power tap, and electrical equipment were not being used in conjunction with a ground-fault circuit interrupter and/or an assured equipment grounding conductor program, on or about June 17, 2025.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $6384

1926.405 B01

Serious Gravity 1 4 instances 8 exposed
Issued
Dec 15, 2025
Abate by
Jan 20, 2026
Penalty
Initial $0 · Current $0
29 CFR 1926.405(b)(1):  Conductors entering boxes, cabinets, or fittings were not protected from abrasion, openings through which conductors enter were not effectively closed, and unused openings in cabinets, boxes, and fittings were not effectively closed:  a.)  4600 Jonestown Road, Harrisburg, PA, former Bon-Ton / new Fun City section of the Colonial Park Mall - Employees were utilizing an energized metallic outlet box to power equipment for work operations.  A yellow junior service flexible cord was wired into a metallic outlet box.  The inner insulated conductors of the junior service flexible cord were exposed to damage on the metal edge of the knockout opening and the opening was not effectively closed as the metal knockout bushing was nor secured into the knockout hole, on or about June 17, 2025.  b.)  4600 Jonestown Road, Harrisburg, PA, former Bon-Ton / new Fun City section of the Colonial Park Mall - Employees were utilizing an energized metallic outlet box to power equipment for work operations.  A metal knockout on the side of the metallic outlet box was missing, exposing employees to shock hazards while handling the box, on or about June 17, 2025.  c.)  4600 Jonestown Road, Harrisburg, PA, former Bon-Ton / new Fun City section of the Colonial Park Mall - Employees were utilizing an energized metallic outlet box to power equipment for work operations.  A yellow junior service flexible cord was wired into the rear of a metallic outlet box.  The inner insulated conductors of the junior service flexible cord were exposed to damage on the metal edge of the knockout opening and the opening was not effectively closed as the metal knockout opening was not equipped with a means to protect the inner insulated conductors and/or effectively close the knockout opening, on or about June 17, 2025.  d.)  4600 Jonestown Road, Harrisburg, PA, former Bon-Ton / new Fun City section of the Colonial Park Mall - Employees were utilizing an energized metallic outlet box to power equipment for work operations.  An orange junior service flexible cord was wired into the side of a metallic outlet box.  The inner insulated conductors of the junior service flexible cord were exposed to damage on the metal edge of the knockout opening and the opening was not effectively closed as the metal knockout opening was not equipped with a means to protect the inner insulated conductors and/or effectively close the knockout opening, on or about June 17, 2025.  e.)  4600 Jonestown Road, Harrisburg, PA, former Bon-Ton / new Fun City section of the Colonial Park Mall - Employees were utilizing an energized metallic outlet box to power equipment for work operations.  A orange junior service flexible cord was wired into a metallic outlet box.  The inner insulated conductors of the junior service flexible cord were exposed to damage on the metal edge of the knockout opening and the opening was not effectively closed as the metal knockout bushing was nor secured into the knockout hole, on or about June 17, 2025.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $0

1926.405 G02 III

Serious Gravity 1 4 instances 7 exposed
Issued
Dec 15, 2025
Abate by
Jan 20, 2026
Penalty
Initial $0 · Current $0
29 CFR 1926.405(g)(2)(iii):  Flexible cords were not used in continuous lengths without splice or tap:  a.)  4600 Jonestown Road, Harrisburg, PA, former Bon-Ton / new Fun City section of the Colonial Park Mall - A gray junior service flexible cord, which was plugged into a receptacle labelled "220V" was spliced with a yellow junior service electrical cord, on or about June 17, 2025.  b.)  4600 Jonestown Road, Harrisburg, PA, former Bon-Ton / new Fun City section of the Colonial Park Mall - A black junior service flexible cord was spliced with an orange junior service electrical cord, on or about June 17, 2025.  c.)  4600 Jonestown Road, Harrisburg, PA, former Bon-Ton / new Fun City section of the Colonial Park Mall - An orange junior service flexible cord and a yellow junior service flexible cord were spliced together, on or about June 17, 2025.  d.)  4600 Jonestown Road, Harrisburg, PA, former Bon-Ton / new Fun City section of the Colonial Park Mall - Two yellow junior service flexible cord were spliced together, on or about June 17, 2025.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $0

1926.416 E01

Serious Gravity 1 1 instance 7 exposed
Issued
Dec 15, 2025
Abate by
Jan 20, 2026
Penalty
Initial $0 · Current $0
29 CFR 1926.416(e)(1):  Worn or frayed electric cords or cables were used:  a.)  4600 Jonestown Road, Harrisburg, PA, former Bon-Ton / new Fun City section of the Colonial Park Mall - The outer jacket of an orange junior service flexible cord was frayed at the cord cap and along the flexible cord, exposing the inner insulated conductors, on or about June 17, 2025.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $0

1926.403 B02

Serious Gravity 1 4 instances 7 exposed
Issued
Dec 15, 2025
Abate by
Jan 20, 2026
Penalty
Initial $6,384 · Current $6,384
29 CFR 1926.403(b)(2):  Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification:  a) 4600 Jonestown Road, Harrisburg, PA, former Bon-Ton / new Fun City section of the Colonial Park Mall - Employees were utilizing a metallic outlet box to power equipment including, but not limited to, a Ryobi circular saw and a Bauer jig saw.  The metal outlet box was not was not installed and used in accordance with instructions included in the listing, labeling, or certification of the product in that metallic box was on the floor and was not flush mount to a surface, on or about June 17, 2025.  b) 4600 Jonestown Road, Harrisburg, PA, former Bon-Ton / new Fun City section of the Colonial Park Mall - Employees were utilizing a metallic outlet box to power equipment including, but not limited to, a portable jobsite light tripod.  The metal outlet box was not was not installed and used in accordance with instructions included in the listing, labeling, or certification of the product in that metallic box was on the floor and was not flush mount to a surface, on or about June 17, 2025.  c) 4600 Jonestown Road, Harrisburg, PA, former Bon-Ton / new Fun City section of the Colonial Park Mall - Employees were utilizing a metallic outlet box to power equipment including, but not limited to, a Ryobi battery charger and Makita battery charger.  The metal outlet box was not was not installed and used in accordance with instructions included in the listing, labeling, or certification of the product in that metallic box was on the floor and was not flush mount to a surface, on or about June 17, 2025.  d) 4600 Jonestown Road, Harrisburg, PA, former Bon-Ton / new Fun City section of the Colonial Park Mall - Employees were utilizing a metallic outlet box to power equipment including, but not limited to, a WEGoodlder MMA-250 welding machine.  The metal outlet box was not was not installed and used in accordance with instructions included in the listing, labeling, or certification of the product in that metallic box was on the floor and was not flush mount to a surface, on or about June 17, 2025.  Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $6384

1926.403 I02 I

Serious Gravity 1 1 instance 7 exposed
Issued
Dec 15, 2025
Abate by
Jan 20, 2026
Penalty
Initial $0 · Current $0
29 CFR 1926.403(i)(2)(i):  Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph:  a.) 4600 Jonestown Road, Harrisburg, PA, former Bon-Ton / new Fun City section of the Colonial Park Mall - A wall-mounted electrical  box was open, exposing employees to energized live parts, on or about June 17, 2025.  Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $0

1926.405 B02

Serious Gravity 1 1 instance 7 exposed
Issued
Dec 15, 2025
Abate by
Jan 20, 2026
Penalty
Initial $0 · Current $0
29 CFR  1926.405(b)(2): All pull boxes, junction boxes, and fittings were not provided with covers:  a.) 4600 Jonestown Road, Harrisburg, PA, former Bon-Ton / new Fun City section of the Colonial Park Mall - An electrical junction box containing wire nut splices was not equipped with a cover plate, on or about June 17, 2025.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $0

View FUN City LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348327321.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.