CINCINNATI, OH —
OSHA Inspection: EMILIO VELASQUEZ ROOFING AND CONSTRUCTION
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of EMILIO VELASQUEZ ROOFING AND CONSTRUCTION in 4182 VINE ST., CINCINNATI, OH 45217 (NAICS 238160). OSHA activity number 348328014.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EMILIO VELASQUEZ ROOFING AND CONSTRUCTION
- Site address
- 4182 VINE ST.
- City
- CINCINNATI
- State
- OH
- ZIP
- 45217
- Mailing
- 3826 LINCOLN RD, CINCINNATI, OH 45247
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 4
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.451 C01 II
- Issued
- Aug 26, 2025
- Abate by
- Sep 29, 2025
- Penalty
- Initial $4,965 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(c)(1)(ii): Guys, ties, and braces shall be installed according to the scaffold manufacturer's recommendations or at the closest horizontal member to the 4:1 height and be repeated vertically at locations of horizontal members every 20 feet (6.1 m) or less thereafter for scaffolds 3 feet (0.91 m) wide or less, and every 26 feet (7.9 m) or less thereafter for scaffolds greater than 3 feet (0.91 m) wide. The top guy, tie or brace of completed scaffolds shall be placed no further than the 4:1 height from the top. Such guys, ties and braces shall be installed at each end of the scaffold and at horizontal intervals not to exceed 30 feet (9.1 m) (measured from one end [not both] towards the other). a.) On or about June 24, 2025, the employer failed to protect employees from a scaffolding tipping hazard by using wire-tie to tie in the scaffolding system to the residential building at 24' instead of the manufacturer recommended and designed tie-ins exposing employees to 24' falls and scaffold tipping hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $4965
1926.451 F03
- Issued
- Aug 26, 2025
- Abate by
- Sep 29, 2025
- Penalty
- Initial $4,965 · Current $2,000 Reduced
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity. a.) On or about June 24, 2025, the employer failed to have a competent person inspect the Bil-Jax scaffolding system for visible defects before the start of the work shift. As a result, the employer failed to identify that the scaffold was secured with modified tie-ins that created a tipping hazard and that the scaffold was erected in direct contact with energized power lines wrapped in a thin rubber material applied by the employer instead of protective measures provided by the utility company. Employees erecting and working from the scaffold were thereby exposed to electrocution hazards and tipping hazards of approximately 24 feet.
Recent events (2)
- — I (S) $2000
- — Z (S) $4965
1926.451 F06
- Issued
- Aug 26, 2025
- Abate by
- Sep 29, 2025
- Penalty
- Initial $4,965 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(f)(6): The clearance between scaffolds and power lines shall be as follows: Scaffolds shall not be erected, used, dismantled, altered, or moved such that they or any conductive material handled on them might come closer to exposed and energized power lines than as follows: *Insulated Lines _____________________________________________________________________ Voltage Minimum distance Alternatives ____________________ ________________________ _______________________ Less than 300 volts. 3 feet (0.9 m) 300 volts to 50 kv. 10 feet (3.1 m) More than 50 kv..... 10 feet (3.1 m) plus 2 times the length 0.4 inches (1.0 cm) of the line for each 1 kv over insulator, but never 50 kv. less than 10 feet (3.1 m). ____________________ ________________________ _______________________ *Uninsulated lines _____________________________________________________________________ Voltage Minimum distance Alternatives ____________________ ________________________ _______________________ Less than 50 kv..... 10 feet (3.1 m). More than 50 kv..... 10 feet (3.1 m) plus 2 times the length of 0.4 inches (1.0 cm) the line insulator, for each 1 kv over but never less than 50 kv. 10 feet (3.1 m). ____________________ ________________________ _______________________ Exception to paragraph (f)(6): Scaffolds and materials may be closer to power lines than specified above where such clearance is necessary for performance of work, and only after the utility company, or electrical system operator, has been notified of the need to work closer and the utility company, or electrical system operator, has deenergized the lines, relocated the lines, or installed protective coverings to prevent accidental contact with the lines. a.) On or about June 24, 2025, the employer failed to maintain the required clearance between the Bil-Jax scaffolding system and an energized 220-volt single-phase power line running from the utility pole to the multi-family building. The scaffold was erected so that the power line was in direct contact with the scaffold, exposing employees erecting and working from the scaffold to electrocution hazards
Recent events (2)
- — I (S) $0
- — Z (S) $4965
More inspections in this industry (NAICS 238160)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348328014.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.