CHICAGO, IL —
OSHA Inspection: MR. TRADE LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MR. TRADE LLC in 2915 JEROME STREET, CHICAGO, IL 60645 (NAICS 238160). OSHA activity number 348333592.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MR. TRADE LLC
- Site address
- 2915 JEROME STREET
- City
- CHICAGO
- State
- IL
- ZIP
- 60645
- Mailing
- 6351 S. KNOX AVENUE, CHICAGO, IL 60629
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 4
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.102 A01
- Issued
- Jul 10, 2025
- Abate by
- Aug 5, 2025
- Penalty
- Initial $2,837 · Current $1,800 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee use appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors or potentially injurious light radiation. a) On June 23, 2025, employees were observed using a pneumatic nail gun without eye or face protection while performing roofing work. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (S) $1800
- — Z (S) $2837
1926.416 A01
- Issued
- Jul 10, 2025
- Abate by
- Aug 5, 2025
- Penalty
- Initial $4,965 · Current $2,500 Reduced
General-duty citation text
29 CFR 1926.416(a)(1): The employer permitted employees to work in close proximity to energized, unguarded, and ungrounded electric power circuits that the employee could contact in the course of their work: a) On June 23, 2025, employees were exposed to electrical shock while working around exposed electrical parts with a voltage of 120/240 volts. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (2)
- — I (S) $2500
- — Z (S) $4965
1926.501 B13
- Issued
- Jul 10, 2025
- Penalty
- Initial $4,965 · Current $2,700 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On June 23, 2025, employees were exposed to fall hazards while performing roofing work on an existing residential building. Employees were not protected against fall hazards while working at an elevation approximately 20.5 feet above ground. No abatement certification or documentation is required for this item.
Recent events (2)
- — I (S) $2700
- — Z (S) $4965
1926.1053 B01
- Issued
- Jul 10, 2025
- Penalty
- Initial $3,547 · Current $2,500 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) On June 23, 2025, employees were performing roofing work to an existing residential building and utilizing an aluminum ladder to access the work area that did not extend three feet past the edge of the roof being accessed. No abatement certification or documentation is required for this item.