OSHA Inspection: KEVIN JAVIER MELGAR RIVERA

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of KEVIN JAVIER MELGAR RIVERA in 4702 KENSINGTON COURT, SACHSE, TX 75048 (NAICS 238160). OSHA activity number 348345448.

Watch Kevin Javier Melgar Rivera — free Get an email when a new federal OSHA severe-injury report for Kevin Javier Melgar Rivera is published. One employer, no account, unsubscribe in one click.
Site address
4702 KENSINGTON COURT
City
SACHSE
State
TX
ZIP
75048
Mailing
9505 BROCKBANK DRIVE, DALLAS, TX 75220
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238160
Employees
7
Ownership type
A

3 citations on file for this inspection.

1926.100 A

Serious Gravity 5 1 instance 7 exposed
Issued
Abate by
Penalty
Initial $4256.00 · Current $4256.00
29 CFR  1926.100(a):Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:  (a)	On or about June 30, 2025, employees doing roof work a new build two (2) stories single family house without the use of hard hats where an overhead hazard exists.
Recent events (1)
  • — Z (S) $4256

1926.501 B13

Serious Gravity 10 2 instances 5 exposed
Issued
Abate by
Penalty
Initial $4965.00 · Current $4965.00
29 CFR  1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b)  (a)	On or about June 30, 2025, employees doing roof work a new build two (2) stories single family house without without having fall protection. a.	9-feet fall hazard b.	18-feet  fall hazard
Recent events (1)
  • — Z (S) $4965

1926.1053 B01

Serious Gravity 10 2 instances 5 exposed
Issued
Abate by
Penalty
Initial $4965.00 · Current $4965.00
29 CFR  1926.1053(b)(1):Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet above the upper landing surface to which the ladder was used to gain access:  On or about June 30, 2025, employees doing roof work on a single family two (2) stories house using extension ladders that did not extend 3-feet above the landing of the roof:  (a)	32-feet extension ladder (b)	14-feet extension ladder