Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MOLDCABLE, INC.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of MOLDCABLE, INC. in 1351 COUNTY ROAD 257, LIBERTY HILL, TX 78642 (NAICS 517311). OSHA activity number 348356445.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Moldcable, INC. — free Get an email when a new federal OSHA severe-injury report for Moldcable, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
MOLDCABLE, INC.
Site address
1351 COUNTY ROAD 257
City
LIBERTY HILL
State
TX
ZIP
78642
Mailing
300 W SOMERDALE RD, SUITE 5, VOORHEES, NJ 08043
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
517311
Employees
2
Ownership type
A

2 citations on file for this inspection.

1910.268 B07

Serious Gravity 10 1 instance 2 exposed
Issued
Jan 6, 2026
Abate by
Feb 2, 2026
Penalty
Initial $14,895 · Current $14,895
29 CFR 1910.268(b)(7): The employer did not ensure that no employee approached or took any conductive object closer to any electrically energized overhead power lines and parts as prescribed in Table R-2 or in (i) - (iii) of this section:  On or about July 7, 2025, an employee used an aluminum telescopic pole within the minimum approach distance of energized power lines.
Recent events (2)
  • — C (S) $14895
  • — Z (S) $14895

1910.268 E

Serious Gravity 10 1 instance 2 exposed
Issued
Jan 6, 2026
Abate by
Feb 2, 2026
Penalty
Initial $14,895 · Current $14,895
29 CFR 1910.268(e): Personal protective equipment, protective devices and special tools needed for the work of employees was not provided and the employer did not ensure the use of such personal protective equipment, protective devices and special tools.  On or about July 7, 2025, an employee did not use personal protective equipment and non-insulated tools near energized power lines.
Recent events (2)
  • — C (S) $14895
  • — Z (S) $14895

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348356445.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.