Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: C BEYER CONTRACTING

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of C BEYER CONTRACTING in 1184 PITTSBURGH ROAD, VALENCIA, PA 16059 (NAICS 238160). OSHA activity number 348359332.

Watch C Beyer Contracting — free Get an email when a new federal OSHA severe-injury report for C Beyer Contracting is published. One employer, no account, unsubscribe in one click.
Establishment
C BEYER CONTRACTING
Site address
1184 PITTSBURGH ROAD
City
VALENCIA
State
PA
ZIP
16059
Mailing
111 LAKEVIEW DRIVE, BUTLER, PA 16001
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
2
Ownership type
A

2 citations on file for this inspection.

1926.501 B13

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $2270.00 · Current $1150.00 Reduced
29 CFR  1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provided for an alternative fall protection measure:  a) Job site, 1184 Pittsburgh Road, Valencia, PA:  On or about July 8, 2025 during roofing activities, the employer did not ensure appropriate fall protection systems/devices were in use where employees were exposed to fall hazards of up to approximately 7 feet.
Recent events (2)
  • — I (S) $1150
  • — Z (S) $2270

1926.1053 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $2270.00 · Current $1150.00 Reduced
29 CFR  1926.1053(b)(1): When portable ladders were used for access to an upper landing surface, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access; or, when such an extension was not possible because of the ladder's length, then the ladder was not secured at its top to a rigid support that would not deflect, and a grasping device, such as a grabrail, was not provided to assist employees in mounting and dismounting the ladder:  a) Job site, 1184 Pittsburgh Road, Valencia, PA:  On or about July 8, 2025 during roofing activities, the employer did not ensure the ladder used to get up/down from the roof was properly set up in that it only extended approximately 1-foot above the roof line.
Recent events (2)
  • — I (S) $1150
  • — Z (S) $2270

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348359332.