Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,892Inspections Most recent open 2026-09-03 Last loaded 2026-09-07

OSHA Inspection: NJ CONTRACTING SOLUTIONS LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of NJ CONTRACTING SOLUTIONS LLC in 115 NORTH 12TH ST., ALLENTOWN, PA 18104 (NAICS 236118). OSHA activity number 348360439.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch NJ Contracting Solutions LLC for free Get an email when a new federal OSHA severe-injury report for NJ Contracting Solutions LLC is published. One employer, no account, unsubscribe in one click.
Site address
115 NORTH 12TH ST.
City
ALLENTOWN
State
PA
ZIP
18104
Mailing
1122 W. HAMILTON BLVD, ALLENTOWN, PA 18101
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Last modified
Data loaded
NAICS code
236118
Employees
4
Ownership type
Private (A)

2 citations on file for this inspection.

1926.21 B02

Serious Gravity 10 1 instance 2 exposed
Issued
Jan 7, 2026
Abate by
Jan 27, 2026
Penalty
Initial $4,965 · Current $6,000
29 CFR  1926.21(b)(2):The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury:  a)  115 N. 12th Street Allentown: On or about July 9, 2025, employees utilizing an articulating elevated work platform were not instructed as to the minimum approach distances of overhead energized electrical distribution lines.
Recent events (2)
  • · I (S) $6000
  • · Z (S) $4965

1926.451 F06

Serious Gravity 10 1 instance 2 exposed
Issued
Jan 7, 2026
Abate by
Jan 27, 2026
Penalty
Initial $4,965 · Current $0 Reduced
29 CFR  1926.451(f)(6): The clearance between scaffolds and power lines was not maintained at greater than 10 feet:  a)  115 N. 12th Street Allentown:  On or about July 9, 2025, employees were utilizing a JLG 450AJ boom lift to perform painting on the exterior of a residential structure.  The employer did not ensure the components of the lift remained at least 10 feet from energized overhead power lines.
Recent events (2)
  • · I (S) $0
  • · Z (S) $4965

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 348360439.