BOX ELDER, SD —
OSHA Inspection: JBS PLUMBING, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of JBS PLUMBING, LLC in 125 WEST GATE ROAD, BOX ELDER, SD 57719 (NAICS 238220). OSHA activity number 348366923.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- JBS PLUMBING, LLC
- Site address
- 125 WEST GATE ROAD
- City
- BOX ELDER
- State
- SD
- ZIP
- 57719
- Mailing
- 6304 NORTHDALE DRIVE, BLACK HAWK, SD 57718
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238220
- Employees
- 6
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.651 J02
- Issued
- Dec 18, 2025
- Abate by
- Jan 22, 2026
- Penalty
- Initial $2,838 · Current $2,838
General-duty citation text
29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary: (a)JBS Plumbing, LLC at 125 West Gate Road, Box Elder, SD 57719: On or about and at times prior to July 9, 2025, the employer did not ensure that excavation spoils piles were at least two feet from the edge of the north excavation. This condition exposed employees to cave-in and struck-by hazards.
Recent events (1)
- — Z (S) $2838
1926.652 A01
- Issued
- Dec 18, 2025
- Abate by
- Jan 22, 2026
- Penalty
- Initial $2,838 · Current $2,838
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c): (a)JBS Plumbing, LLC at 125 West Gate Road, Box Elder, SD 57719: On or about and at times prior to July 9, 2025, the employer did not ensure that a protective system was in place in an excavation greater than five feet in depth prior to employees entering to conduct water line work within a vertical walled trench. This condition exposed employees to cave-in and struck-by hazards.
Recent events (1)
- — Z (S) $2838
1926.651 K01
- Issued
- Dec 18, 2025
- Abate by
- Jan 22, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could result in possible cave-ins, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions: (a)JBS Plumbing, LLC at 125 West Gate Road, Box Elder, SD 57719: On or about and at times prior to July 9, 2025, the employer did not ensure a competent person inspected the excavation prior to start of work and during each shift, in that the competent person did not implement an appropriate protective system and did not take prompt corrective action to eliminate the cave-in hazard. This condition exposed employees to struck-by and cave-in hazards.
Recent events (1)
- — Z (S) $0
1926.651 B04
- Issued
- Dec 18, 2025
- Abate by
- Jan 22, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.651(b)(4): The employer did not ensure that while the excavation was open, underground installations were protected, supported, or removed as necessary to safeguard employees: (a)JBS Plumbing, LLC at 125 West Gate Road, Box Elder, SD 57719: On or about and at times prior to July 9, 2025, the employer did not ensure that employees were protected from accidental damage to unsupported gas lines on the south trench. This condition exposed employees to burn and explosion hazards.
Recent events (1)
- — Z (O) $0
More inspections at JBS Plumbing, LLC
View JBS Plumbing, LLC's full OSHA safety record →
More inspections in this industry (NAICS 238220)
More inspections in SD
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348366923.