SAN ANTONIO, TX —
OSHA Inspection: M&M METALS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of M&M METALS in 103 BRANIFF DRIVE, SAN ANTONIO, TX 78216 (NAICS 332999). OSHA activity number 348367194.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- M&M METALS
- Site address
- 103 BRANIFF DRIVE
- City
- SAN ANTONIO
- State
- TX
- ZIP
- 78216
- Mailing
- 103 BRANIFF DRIVE, SAN ANTONIO, TX 78216
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 88
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.212 A03 II
- Issued
- Dec 3, 2025
- Penalty
- Initial $8,276 · Current $4,966 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii):Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s). On or about July 11, 2025, employees in the fabrication shop were utilizing a hydraulic sheet metal shear that was not guarded in a way to prevent employees from accessing the cutting blade.
Recent events (2)
- — I (O) $4965.6
- — Z (S) $8276
1910.212 B
- Issued
- Dec 3, 2025
- Penalty
- Initial $5,627 · Current $3,376 Reduced
General-duty citation text
29 CFR 1910.212(b):Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving. On or about July 11, 2025, the drill press located in the upstairs backshop was not secured in in a way to prevent walking or moving.
Recent events (2)
- — I (O) $3376.2
- — Z (S) $5627
1910.219 C04 II
- Issued
- Dec 3, 2025
- Penalty
- Initial $5,627 · Current $3,376 Reduced
General-duty citation text
29 CFR 1910.219(c)(4)(ii):The unused keyway(s) of projecting shaft end(s) were not filled up or covered. On or about July 11, 2025, employees were exposed to unguarded rotating projected shaft ends with unused keyways while operating and working around the coil line machinery.
Recent events (2)
- — I (O) $3376.2
- — Z (S) $5627
1910.219 E01 I
- Issued
- Dec 3, 2025
- Abate by
- Jan 23, 2026
- Penalty
- Initial $6,620 · Current $3,972 Reduced
General-duty citation text
29 CFR 1910.219(e)(1)(i):Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed by guards conforming to requirements specified in 29 CFR 1910.219(m) and (o). On or about July 11, 2025, employees were exposed to unguarded horizontal belts 42 inches or less from the floor during coil line operations.
Recent events (2)
- — I (O) $3972
- — Z (S) $6620
1910.305 B02 I
- Issued
- Dec 3, 2025
- Penalty
- Initial $4,965 · Current $2,979 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i):Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: Instance B: On or about July 11, 2025, employees were exposed to live electric components on a 15 amp / 120 volt plug outlet located in the duct shop (rear left corner) having the faceplate not fully secured. Instance C: On or about July 11, 2025, employees were exposed to live electric components due to a 15 amp / 120 volt plug outlet located in the duct shop (front corner) having a broken receptacle cover.
Recent events (2)
- — I (O) $2979
- — Z (S) $4965
1910.334 A02 I
- Issued
- Dec 3, 2025
- Penalty
- Initial $4,220 · Current $2,532 Reduced
General-duty citation text
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket): On or about July 11, 2025, and at times prior thereto, the employer was not visually inspecting flexible cords for any external defects prior to use on any shift.
Recent events (2)
- — I (O) $2532
- — Z (S) $4220
More inspections at M&M Metals
View M&M Metals's full OSHA safety record →
More inspections in this industry (NAICS 332999)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348367194.