Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: IVAN VEGA RIOS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of IVAN VEGA RIOS in 45 PARKWOOD DRIVE LOT 57, DAWSONVILLE, GA 30534 (NAICS 238130). OSHA activity number 348369935.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ivan Vega Rios — free Get an email when a new federal OSHA severe-injury report for Ivan Vega Rios is published. One employer, no account, unsubscribe in one click.
Establishment
IVAN VEGA RIOS
Site address
45 PARKWOOD DRIVE LOT 57
City
DAWSONVILLE
State
GA
ZIP
30534
Mailing
6410 CASTLE DOWNS TRAIL, LITHONIA, GA 30058
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238130
Employees
5
Ownership type
A

4 citations on file for this inspection.

1926.102 A01

Serious Gravity 1 1 instance 1 exposed
Issued
Aug 25, 2025
Penalty
Initial $2,128 · Current $2,128
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury:  a) New single-family residential construction located on lot #57 at 45 Parkview Drive, Dawsonville, GA 30534, Second-level and top plate: On or about 07/01/2025, the employer exposed employees to struck-by hazards while operating pneumatic nail guns, in that protective eyewear was not provided to employees engaged in framing activities.
Recent events (1)
  • — Z (S) $2128

1926.501 B13

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 25, 2025
Penalty
Initial $2,837 · Current $2,837
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m)  or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501(b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502:     a) New single-family residential  structure located on lot #57 at 45 Parkview Drive, Dawsonville, GA 30534 Second level top plate: On or about 07/01/2025, the employer exposed employees to fall hazards of approximately 18-feet, 8-inches to the lower ground level, in that a fall protection system was not provided while engaged in framing activities.
Recent events (1)
  • — Z (S) $2837

1926.1053 B01

Serious Gravity 1 1 instance 4 exposed
Issued
Aug 25, 2025
Penalty
Initial $2,128 · Current $2,128
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:   a) New single-family residential  structure located on lot #57 at 45 Parkview Drive, Dawsonville, GA 30534 Second level: On or about 07/01/2025, the employer exposed employees to fall hazards of approximately 11-feet to the lower ground level, in that the ladder used to access the upper landing did not extend at least 3-feet past the upper landing to allow for safe access.
Recent events (1)
  • — Z (S) $2128

1926.405 A02 II I

Other-than-serious 1 instance 1 exposed
Issued
Aug 25, 2025
Penalty
Initial $0 · Current $0
29 CFR 1926.405(a)(2)(ii)(I): Flexible cords and cables used for temporary wiring were not protected from damage:  a) New single-family residential  structure located on lot #57 at 45 Parkview Drive, Dawsonville, GA 30534 Ground/Street: On or about 07/01/2025, the employer did not provide protection for a flexible cord used to power a ROLAIR air compressor that was run across an active roadway.
Recent events (1)
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348369935.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.