PITTSFIELD, NH —
OSHA Inspection: H&H EXTERIORS INC.
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of H&H EXTERIORS INC. in 343 TILTON HILL ROAD, PITTSFIELD, NH 03263 (NAICS 236210). OSHA activity number 348375114.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- H&H EXTERIORS INC.
- Site address
- 343 TILTON HILL ROAD
- City
- PITTSFIELD
- State
- NH
- ZIP
- 03263
- Mailing
- 272 LOUDON ROAD, PITTSFIELD, NH 03263
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236210
- Employees
- 20
- Ownership type
- A
Citations
1 citation on file for this inspection.
1926.501 A02
- Issued
- Jan 5, 2026
- Abate by
- Jan 9, 2026
- Penalty
- Initial $33,103 · Current $33,103
General-duty citation text
29 CFR 1926.501(a)(2): The employer did not determine if the walking/working surfaces on which its employees were working had the strength and structural integrity to support employees safely. Employees were allowed to work on those surfaces that did not have the requisite strength and structural integrity: On or about July 15, 2025, on the section of building which was 60 feet by 90 feet (office), employees setting roof trusses were exposed to fall hazards where prefabricated wood roof trusses and exterior building walls were not adequately braced during installation. The roof trusses (approximately 12 trusses) and exterior building walls which were set on July 15, 2025, were not adequately braced such that there was inadequate temporary bracing for the structure. Employees working on these walking / working surfaces were exposed to falls such that they did not have the requisite strength and structural integrity. On or about July 15, 2025, on the section of building which was 60 feet by 100 feet (shop), employees setting roof trusses were exposed to fall, struck by, and caught between hazards where prefabricated wood roof trusses were not adequately braced during installation. The roof trusses (approximately 4 trusses) and exterior building walls which were set on July 15, 2025, were not adequately braced such that there was inadequate temporary bracing for the structure. These conditions contributed to the collapse of the 4 installed trusses where two employees were injured and transported to the hospital. Employees working on these walking / working surfaces were exposed to falls such that they did not have the requisite strength and structural integrity. On or about July 22, 2025, on the section of building which was 60 feet by 90 feet (office), employees setting roof trusses were exposed to fall, struck by, and caught between hazards where prefabricated wood roof trusses were not adequately braced during installation. The roof truss which were set on July 15, 2025 (approximately 46 trusses) and exterior building walls and roof trusses which were set on July 22, 2025 (approximately 34 trusses) , were not adequately braced such that there was inadequate temporary bracing for the structure. Employees working on these walking / working surfaces were exposed to falls such that they did not have the requisite strength and structural integrity. On or about July 23, 2025, on the section of building which was 60 feet by 100 feet (shop), employees setting roof trusses were exposed to fall, struck by, and caught between hazards where prefabricated wood roof trusses were not adequately braced during installation. The roof trusses (approximately 51 trusses) and exterior building walls which were set on July 23, 2025, were not adequately braced such that there was inadequate temporary bracing for the structure. These conditions contributed to the collapse of all the 50 installed trusses where two employees were injured and transported to the hospital. Employees working on these walking / working surfaces were exposed to falls such that they did not have the requisite strength and structural integrity.
Recent events (1)