FIRESTONE, CO —
OSHA Inspection: FRONTIER STONE LLC
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of FRONTIER STONE LLC in 5528 & 5578 TAMARACK AVE., FIRESTONE, CO 80504 (NAICS 238140). OSHA activity number 348384215.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FRONTIER STONE LLC
- Site address
- 5528 & 5578 TAMARACK AVE.
- City
- FIRESTONE
- State
- CO
- ZIP
- 80504
- Mailing
- 3587 STONE CANYON RD., LONGMONT, CO 80503
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 25
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.300 B03
- Issued
- Sep 10, 2025
- Abate by
- Oct 6, 2025
- Penalty
- Initial $2,837 · Current $1,986 Reduced
General-duty citation text
29 CFR 1926.300(b)(3): One or more methods of machine guarding were not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: 5528 & 5578 Tamarack Ave., Firestone CO: On or about July 17, 2025, the company's 4.5-inch, DeWalt right angle hand grinder (Model #: DWE402) was used without an affixed guard. Employees using the unguarded hand grinder and others in the immediate area were not protected from hazards created by flying chips and sparks and/or struck-by hazards from the abrasive wheel if it were to break.
Recent events (2)
- — I (S) $1985.9
- — Z (S) $2837
1926.403 B01
- Issued
- Sep 10, 2025
- Penalty
- Initial $3,547 · Current $2,483 Reduced
General-duty citation text
29 CFR 1926.403(b)(1): Employer did not ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees: 5528 & 5578 Tamarack Ave., Firestone CO: On or about July 17, 2025, the employer failed to ensure that the company's 12-gauge (flexible) extension cord use to power handheld tools such as but not limited to, a Dewalt right hand angle grinder was free from damage. The outer sheath was cut exposing internal wiring and attempts at repair, were done using electrical tape. Employees using the extension cord were not protected from hazards created by inadvertent/accidental contact with live electrical parts.
Recent events (2)
- — I (S) $2482.9
- — Z (S) $3547
1926.451 C02 I
- Issued
- Sep 10, 2025
- Abate by
- Oct 6, 2025
- Penalty
- Initial $4,256 · Current $2,979 Reduced
General-duty citation text
29 CFR 1926.451(c)(2)(i): Footings were not level, sound, rigid, and capable of supporting the loaded scaffold without settling or displacement: 5528 & 5578 Tamarack Ave., Firestone CO: On or about July 17, 2025, tubular steel scaffolding used by employees engaged in masonry work was not placed on solid and stable ground. The employer did not ensure the surface ground area was properly graded causing the scaffolding to lean approximately 2 degrees. The unleveled scaffold was not properly supported by a base plate.
Recent events (2)
- — I (S) $2979.2
- — Z (S) $4256
1926.1153 C01
- Issued
- Sep 10, 2025
- Penalty
- Initial $2,837 · Current $1,986 Reduced
General-duty citation text
29 CFR 1926.1153(c)(1): For each employee engaged in a task identified on Table 1, the employer did not fully and properly implement the engineering controls, work practices, and respiratory protection specified for the task on Table 1, unless the employer assesses and limits the exposure of the employee to respirable crystalline silica in accordance with paragraph (d) of this section: 5528 & 5578 Tamarack Ave., Firestone CO: On or about July 17, 2025, the employer did not ensure that employees were protected from respirable crystalline silica hazards while cutting concrete. Respirators and/or water to dissipate plumes of respirable crystalline silica dust were not introduced into the workplace
Recent events (2)
- — I (S) $1985.9
- — Z (S) $2837
More inspections at Frontier Stone LLC
View Frontier Stone LLC's full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348384215.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.