Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RICHARDS-WILCOX, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of RICHARDS-WILCOX, INC. in 600 SOUTH LAKE STREET, AURORA, IL 60506 (NAICS 337214). OSHA activity number 348386749.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Richards-Wilcox, INC. — free Get an email when a new federal OSHA severe-injury report for Richards-Wilcox, INC. is published. One employer, no account, unsubscribe in one click.
Site address
600 SOUTH LAKE STREET
City
AURORA
State
IL
ZIP
60506
Mailing
600 SOUTH LAKE STREET, AURORA, IL 60506
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337214
Employees
110
Ownership type
A

3 citations on file for this inspection.

1910.147 D

Deleted Serious Gravity 10 2 instances 2 exposed
Issued
Sep 30, 2025
Abate by
Oct 28, 2025
Penalty
Initial $11,916 · Current $0 Reduced
29 CFR  1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):  a) On or about July 19, 2025, the employer did not ensure that employees implemented energy control steps prior to performing servicing and maintenance activities on the 500 ton-Danly Press.  Hazardous  energy was not isolated prior to employees  setting up the equipment, exposing them to struck-by and caught-between hazards from moving parts in the event of unexpected movement of the Danly press.  b) On or about August 13,  2025, the employer did not ensure that employees implemented energy control steps prior to performing servicing and maintenance activities on the 500 ton-Danly Press.  Hazardous  energy was not isolated prior to employees  setting up the equipment, exposing them to struck-by and caught-between hazards from moving parts in the event of unexpected movement of the Danly press.  As a result, the remaining applicable energy control elements, involving machine isolation [1910.147(d)(3)], lockout/tagout device application [1910.147(d)(4)], dissipation of residual energy [1910.147(d)(5)(i)], and verification of isolation [1910.147(d)(6)] were not implemented to protect employees from machine hazards.   Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $0
  • — Z (S) $11916

1910.37 B06

Other-than-serious 1 instance 1 exposed
Issued
Sep 30, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.37(b)(6):Each exit sign must be illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color. Self-luminous or electroluminescent signs that have a minimum luminance surface value of at least .06 footlamberts (0.21 cd/m2) are permitted.  On or about  July 21, 2025 the employer did not ensure that the Exit sign on the entrance to the Training Room was illuminated.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 F06 II

Other-than-serious 1 instance 1 exposed
Issued
Sep 30, 2025
Penalty
Initial $0 · Current $0
29 CFR  1910.1200(f)(6)(ii):  Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical:    On or about July 21 2025, the employer did not ensure that a container with the Coolant SYN 2750 was labeled with the product identifier thereby exposing employees to  irritation hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Richards-Wilcox, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348386749.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.